Adam Equipment CBC SERIES Manual
Adam Equipment CBC SERIES Manual

Adam Equipment CBC SERIES Manual

Hide thumbs Also See for CBC SERIES:

Advertisement

Adam Equipment
CBC&CBC-M SERIES
(P.N. 3026610534, Revision A3, July 2013)
Adam Equipment strives to be more environmentally focused and uses recycled materials and
environmentally friendly packaging where possible. As part of this initiative we have developed a short form
manual that uses less paper and ink to describe the main functions of your new Adam scale. A complete
version is available at www.adamequipment.com. Thank you for your support of Adam Equipment and we
hope that you enjoy your new scale.
© Adam Equipment Company 2013
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CBC SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for Adam Equipment CBC SERIES

  • Page 1 Adam scale. A complete version is available at www.adamequipment.com. Thank you for your support of Adam Equipment and we hope that you enjoy your new scale.
  • Page 2: Table Of Contents

    ACCUMULATED TOTALS ..................4 RS-232 INTERFACE ....................6 PARAMETERS ......................6 AUTO SLEEP FUNCTION ...................6 CBC PARAMETERS....................7 CALIBRATION ......................7 BATTERY AND BACKLIGHT OPERATION .............8 BATTERY......................8 BACKLIGHT FOR LCD ..................8 SPECIFICATIONS ....................9 ERROR CODES .....................12 10.0 SERVICE INFORMATION ..................13 © Adam Equipment Company 2013...
  • Page 3: Operation

    3) When the container is removed a negative value will be shown. The indicator above “Zero” will also be on because the platform is back to the same condition as it was when the [Zero] key was pressed last. © Adam Equipment Company 2013...
  • Page 4: Setting The Weighing Unit (Cbca Series Only)

    1) Enter the numeric value to be stored using the numeric keys. Then press the [Pst] key to store the value. 2) To clear the value from the memory and thereby turn off the check-weighing feature, enter the value "0" and press [Pst]. ACCUMULATED TOTALS © Adam Equipment Company 2013...
  • Page 5 To enable this function please see the complete manual for details NOTE: The scale must return to zero or a negative number, before another sample can be added to the memory. © Adam Equipment Company 2013...
  • Page 6: Rs-232 Interface

    “0” Auto sleep mode disabled “1” Auto sleep after 1 minute “5” Auto sleep after 5 minutes “10” Auto sleep after 10 minutes Press [Tare] to set the value. The scale returns to zero. © Adam Equipment Company 2013...
  • Page 7: Cbc Parameters

    Record the new password number in a secure place. CALIBRATION The CBC-M approved scales are sealed to prevent unauthorised calibration. Contact Adam Equipment or your supplier for more details. The CBC scales are calibrated using metric weights and the CBCa scales can be calibrated using either metric or pound weights, depending on the unit in use before calibration.
  • Page 8: Battery And Backlight Operation

    9 before returning to normal operation. “SPAn” “FAIL” 8) If an error message is displayed, then re-check the calibration and repeat the process, if necessary. Suggested Calibration weights for CBC Series: CBC 4 / CBC 8 / CBC 16 / CBC 32 /...
  • Page 9: Specifications

    Model: CBC 100a UNITS OF MAXIMUM TARE READABILITY REPEATIBILITY LINEARITY MEASURE CAPACITY RANGE Kilograms 48.000 kg -48 kg 0.002 kg 0.002 kg 0.004 kg Pounds 100 lb -99 lb 0.005 lb 0.005 lb 0.01 lb © Adam Equipment Company 2013...
  • Page 10: Common Specifications

    Parts counting, check-counting, weighing, accumulating memory, pre-set count with alarm Interface RS-232 bi-directional interface English, German, French, Spanish selectable text Date/Time Real Time Clock (RTC), To print date and time information (Dates in year/month/day, day/month/year or month/day/year formats- Battery backed) © Adam Equipment Company 2013...
  • Page 11 Parts counting, weighing, accumulating memory, Check-count with alarm Interface RS-232 bi-directional interface English, German, French, Spanish selectable text Date/Time Real Time Clock (RTC), To print date and time information (Dates in year/month/day, day/month/year or month/day/year formats- Battery backed) © Adam Equipment Company 2013...
  • Page 12: Error Codes

    Improper calibration of the scale. [Zero] key is pressed Damaged load cell. Damaged Electronics. A/D count is not correct when Platform is not installed. Err 6 turning the scale on. Damaged Load cell. Damaged Electronics. © Adam Equipment Company 2013...
  • Page 13: 10.0 Service Information

    Include any recent history of the unit. For example: -Has it been working since it’s delivered -Has it been in contact with water -Damaged from a fire -Electrical Storms in the area -Dropped on the floor, etc. © Adam Equipment Company 2013...
  • Page 14: Warranty Information

    WARRANTY INFORMATION Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equipment Company.
  • Page 15 Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device. Changes or modifications not expressly approved by Adam Equipment could void the user's authority to operate the equipment. WEEE COMPLIANCE...