Adam Equipment CBK series User Manual

Adam Equipment CBK series User Manual

Hide thumbs Also See for CBK series:

Advertisement

BALANCES.COM
Adam Equipment
CBK SERIES
(P.N. 8509, Revision A7, August 2007)
Software Rev.: 4.28 & above
4.25H & above for CBK 8H/16aH
© Adam Equipment Company 2007

Advertisement

Table of Contents
loading

Summary of Contents for Adam Equipment CBK series

  • Page 1 BALANCES.COM Adam Equipment CBK SERIES (P.N. 8509, Revision A7, August 2007) Software Rev.: 4.28 & above 4.25H & above for CBK 8H/16aH © Adam Equipment Company 2007...
  • Page 2 BALANCES.COM © Adam Equipment Company 2007...
  • Page 3: Table Of Contents

    13.1 CHECK WEIGHING PARAMETERS ..............24 13.2 RS-232 PARAMETERS ..................26 13.3 SCALE PARAMETERS ..................27 14.0 ERROR MESSAGES ..................... 29 15.0 REPLACEMENT PARTS AND ACCESSORIES ............ 30 16.0 SERVICE INFORMATION..................30 17.0 WARRANTY INFORMATION................. 31 18.0 APPENDIX ......................32 © Adam Equipment Company 2007...
  • Page 4: Introduction

    • There are two series within the range. The CBKa series are similar to the CBK series except the CBKa scales can operate in both imperial and metric weighing units, whereas for the CBK series the imperial units are not available.
  • Page 5: Specifications

    8000 g 16000 g 32000 g 48000 g Readability 0.1 g 0.1 g 0.2 g 0.5 g Repeatability (S.D.) 0.1 g 0.1 g 0.2 g 0.5 g Linearity (±) 0.2 g 0.2 g 0.4 g © Adam Equipment Company 2007...
  • Page 6: Installation

    BALANCES.COM OTHER SPECIFICATIONS Units of measure CBK Series- kg, g CBKa Series- kg, g, lb, oz, lb:oz Interface RS-232 bi-directional Interface Stabilisation Time 2 Seconds typical Operating Temperature -10° C to 40° C 14° F to 104° F Power supply...
  • Page 7: Locating

    Avoid air movement such as from fans or • opening doors. Do not place near open windows or air-conditioning vents. Keep the scales clean. Do not stack material • on the scales when they are not in use. © Adam Equipment Company 2007...
  • Page 8: Setting Up

    BALANCES.COM SETTING UP • The CBK Series comes with a stainless steel platform packed separately. • Place the platform in the locating holes on the top cover. • Do not press with excessive force as this could damage the load cell inside.
  • Page 9: Keypad

    RS-232 interface. also adds the value to the accumulation memory if the accumulation function is not automatic. [1] to [0] Allow entering numerical values where required, setting of limits, time and date and [CE] for example. © Adam Equipment Company 2007...
  • Page 10: Display

    Weight below the low limit Amber Within the limits Green Above the high limit NOTE: The LED’s can be set by the user to off, bar or spot mode. See “F3 LED” in section 13.1 © Adam Equipment Company 2007...
  • Page 11: Battery

    9.0 AUTO POWER OFF The auto power off can be set by the user to disable the feature or to a pre- set time interval. See setting of the parameter “S3 AoF “ in section 13.3. © Adam Equipment Company 2007...
  • Page 12: Operations

    • As a product is added only the weight of the product will be shown. The scale could be tared a second time if another type of product was to be added to the first one. Again only the weight that is added after taring will be displayed. © Adam Equipment Company 2007...
  • Page 13: Preset Tare

    10.4 PARTS COUNTING The scale can be used to count parts based on the average weight of a sample weighed on the scale. When more parts are added the total number of parts is displayed. © Adam Equipment Company 2007...
  • Page 14 10.2.2. • During parts counting the display can be changed to show the net weight, unit weight and number of parts by each time pressing the [Func] key. © Adam Equipment Company 2007...
  • Page 15: Check-Weighing

    Mass is between the limits Mass is below the low limit 2. The limits can be locked by the manager. A Limit Password must be used to change the limits or recall other limits from memory. © Adam Equipment Company 2007...
  • Page 16: Setting Up Check-Weighing While Weighing

    To disable the check weighing function, enter zero into both the limits as described above. When the current limits are shown, press [CE] to clear the settings, enter zero and then press [Tare] to store the zero values. © Adam Equipment Company 2007...
  • Page 17: Limits Storing And Recalling

    “rEC X” will be displayed for 2 seconds indicating the values stored in the location “X” is being recalled. The scale will change recalled limits, weighing units and settings for the beeper and bar graph. © Adam Equipment Company 2007...
  • Page 18: Percent Weighing

    [Tare] will return the scale will return to weighing. • Remove the sample weight. Then any other weight placed on the scale will be displayed as a percentage of the original sample. For example, © Adam Equipment Company 2007...
  • Page 19: Accumulated Total

    102.13% as an increase of one scale division (0.5g) to 24.0g will be equivalent to an increase of 2.13%. 10.8 ACCUMULATED TOTAL The scale can be set to accumulate when a weight is added to the scale automatically or manually by pressing [Print]. See Section 13.2. © Adam Equipment Company 2007...
  • Page 20: Manual Accumulation

    The display will show "ACC 2" for 2 seconds and then show the new total. • Continue until all weights have been added. This can continue for up to 99 entries until the capacity of display is exceeded. © Adam Equipment Company 2007...
  • Page 21: Automatic Accumulation

    2. In all cases the scale must return to zero or a negative number, before another sample can be added to the memory. 3. More products can be added and [Print] be pressed again for up to 99 entries until the capacity of display is exceeded. © Adam Equipment Company 2007...
  • Page 22: Rs-232 Interface

    BALANCES.COM 11.0 RS-232 INTERFACE The CBK Series are supplied with bi-directional RS-232 interface as standard. The scale when connected to a printer or computer outputs the weight with the selected weighing unit through the RS-232 interface. Specifications: RS-232 output of weighing data...
  • Page 23 1.234 Kg <cr><lf> Net Weight (or Gross wt.) <cr><lf> <cr><lf> Data Format- Continuous Output- Parts Counting: Net Weight (or Gross wt.) 1.234 Kg <cr><lf> Kg and g for metric and Lb for pounds U.W. 123 g <cr><lf> 10 pcs <cr><lf> <cr><lf> <cr><lf> © Adam Equipment Company 2007...
  • Page 24: Input Commands Format

    Sets the zero point for all subsequent weighing. The display Z<cr><lf> shows zero. Prints the results to a PC or printer using the RS-232 P<cr><lf> interface. It also adds the value to the accumulation memory if the accumulation function is not set to automatic. © Adam Equipment Company 2007...
  • Page 25: Calibration

    (if entered directly). Remove the calibration mass. • If an error message “FAIL H” or “FAIL L” is shown, re-check the calibration and repeat. If the error cannot be corrected contact your supplier. © Adam Equipment Company 2007...
  • Page 26: Parameter Settings

    - sets the lock for re-setting the check weighing limits - enables or disables the check weighing LED indicator - enables or disables the check weighing alarm - sets the User Password for check weighing - enables or disables the negative check weighing © Adam Equipment Company 2007...
  • Page 27 The Check weighing password is separate from the scale password, see section 13.3. If the password is other than 0000, user must enter the password to gain access to “F2 LLk”, “F3 LEd”, “F4 bEP”, “F5 CPS” and “F6 nCK ”. © Adam Equipment Company 2007...
  • Page 28: Rs-232 Parameters

    AC oFF C5 Ln Select Language EnGLi EnGLi (English) FrEnCH (French) GErmAn (German) SPAn (Spanish) C6 UId Set User ID To be entered manually 000000 Set Scale ID To be entered manually C7 Sid 000000 © Adam Equipment Company 2007...
  • Page 29: Scale Parameters

    This group of parameters are used to control the operation of the scale. Parameter Description Options Default setting Enable or disable weighing S1 Un units, will not allow to disable all units, at least one has to be enabled. lb:oz © Adam Equipment Company 2007...
  • Page 30 Must be entered twice when asked. When complete, will display donE “ ”. Calibration Calibrate the scale. See S8 CAL Section 10.0 © Adam Equipment Company 2007...
  • Page 31: Error Messages

    Calibration error Improper calibration (should be within FAIL H +10% of the factory calibration). The old FAIL L calibration data will be retained until the calibration process is complete. © Adam Equipment Company 2007...
  • Page 32: Replacement Parts And Accessories

    BALANCES.COM 15.0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories, contact your supplier or Adam Equipment. A partial list of such items is as follows- • Main Power cord • Stainless Steel Pan • Replacement Battery •...
  • Page 33: Warranty Information

    BALANCES.COM 17.0 WARRANTY INFORMATION Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equipment Company.
  • Page 34: Appendix

    BALANCES.COM 18.0 APPENDIX © Adam Equipment Company 2007...
  • Page 35 Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device. Changes or modifications not expressly approved by Adam Equipment could void the user's authority to operate the equipment. WEEE COMPLIANCE...
  • Page 36 For a complete listing of all Adam products visit our website at www.adamequipment.com © Copyright by Adam Equipment Co. Ltd. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment.

Table of Contents