2.2 Positioning, installation
Installation conditions for balanced flue operation (boiler type C)
As device type C
, C
13x
33x
C
to TRGI '86/96, the Vitodens can be
63x
installed for balanced flue operation,
independent of the size or ventilation of
the boiler room.
It may, for example, be installed in rooms
with personnel traffic or in living spaces,
in ancillary rooms without ventilation, in
cupboards (open top) and niches without
maintaining minimum clearances to
combustible components as well as in
attic rooms (pitched attics and long pane
rooms of a roof) where the balanced flue
air supply/exhaust pipe can be directly
routed through the roof.
The flue pipe union for balanced flue
operation is surrounded by combustion
2
air (coaxial pipe). Consequently,
clearances towards combustible
components are not required (further
details on page 128).
The installation location must be safe
from the risk of frost.
Provide a condensate drain and a
blow-off line for the safety valve in the
boiler room.
Electrical interlocks with extraction
devices (cooker hoods etc.) are not
required with balanced flue operation.
Vitodens 300 with 66 kW
Install the Vitodens 300 with 66 kW in
accordance with the Combustion Order
(FeuVo) [or local regulations] in a
separate boiler room. Fit the mains
isolator outside the installation room.
Ventilation air and extract air apertures
are required in accordance with TRGI (see
page 127).
60
, C
, C
or
Installation in a garage
43x
53x
Tests carried out [in Germany] by the
Gaswärme Institutes e. V., Essen, have
confirmed, that the Vitodens is suitable
for installation in garages (certification on
request).
When installing this boiler in garages,
maintain a distance between the floor and
the burner of at least 500 mm. Secure the
boiler on site with a bracket or deflector
against mechanical damage.
Operation of the Vitodens in wet areas
The Vitodens is approved for installation
in wet areas (e.g. bath or shower rooms)
(
protection IP X4 D, splash-proof
When installing the Vitodens in wet areas,
observe the safety areas and minimum
wall clearances according to VDE 0100 [or
local regulations] (see also "Electrical
protection area" on page 61). The
Vitodens 200 and 300 may be installed in
safety area 1.