Viessmann Vitodens 200 Technical Manual page 152

4.2 kw to 66.0 kw
Hide thumbs Also See for Vitodens 200:
Table of Contents

Advertisement

4.2 Design and sizing information for connection on the flue gas side
Plastic (PPs) balanced flue system for routing multiple pipes through one air/flue gas chimney (LAS chimney positive pressure)
(type C
according to TRGI '86/96)
43x
System for balanced flue operation,
specifically developed for the
Vitodens 200.
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
3 4 5 6
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
4
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
max. 3 m
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
qW
qW
qW
qW
qW
qW
qW
qW
qW
qW
qW
qW
qW
qW
qW
qW
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
A Flue gas
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
B Ventilation air
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
C Inspection aperture
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
D Condensate drain with siphon
152
Duct cross-section:
square 160 × 160 mm to 250 × 250 mm
round ∅ 170 to 300 mm.
Up to 5 Vitodens 200 can be connected to
a single flue gas system.
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
qP
qP
qP
qP
qP
qP
qP
qP
qP
qP
qP
qP
qP
qP
qP
qP
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
qQ
qQ
qQ
qQ
qQ
qQ
qQ
qQ
qQ
qQ
qQ
qQ
qQ
qQ
qQ
qQ
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1 Flue outlet
(part of the standard boiler delivery)
2 Basic duct set
(PPs, rigid)
comprising:
H Support bend
H Support rail
H Duct cover (PPs)
H Spacers (3 pieces)
Spacers (3 pieces)
8 Balanced flue bend
87º (1 piece)
45º (2 pieces)
or
Balanced flue inspection tee piece
87º (1 piece)
4 Balanced flue inspection piece, straight
(1 piece)
5 Balanced flue sliding coupling
Fixing clamp, white (1 piece)
(balanced flue pipe)
6 Wall bezel
7 Balanced flue pipe
1 m long
0.5 m long
8 Connecting assembly multiple connection
comprising:
H Inspection pipe ∅ 100
H Flue gas connection ∅ 80
H Fixing clamp
H Spacers
H Longitudinal connection ∅ 100
9 Connecting clamp
required for every duct joint
qP Flue pipe
2 m long (2 pieces @ 2 m = 4 m)
2 m long (1 piece)
1 m long (1 piece)
0.5 m long (1 piece)
Flue pipe
(for corbelled chimneys)
30º (2 pieces)
15º (2 pieces)
qQ Inspection piece, straight (1 piece)
qW Condensate drain connection (eccentric)
Reduction from ∅ 100 mm to ∅ 40 mm
System size
∅ mm
100
100
80
80
80
80
80
80
80
80
80
100
100
100
100
100
100
100
100
100
100
VITODENS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 300Vitodens 333Vitodens 343

Table of Contents