Specification - Viessmann Vitodens 200 Technical Manual

4.2 kw to 66.0 kw
Hide thumbs Also See for Vitodens 200:
Table of Contents

Advertisement

1.2 Specification

Gas fired boiler, series C
,
3
Category II
2ELL 3P
*1
Rated output range
T
/T
= 50/30 ºC
V
R
T
/T
= 80/60 ºC
V
R
Rated thermal load
Product ID
Gas supply pressure
Natural gas
LPG
Max. permissible gas supply pressure
Natural gas
LPG
Max. power consumption
(incl. circulation pump)
Weight
Capacity Heat exchanger
Max. volume flow
(limits for the use of a hydraulic decoupler)
Rated circulation water volume
at ΔT = 20 K
Diaphragm expansion vessel
Content
Inlet pressure
Permissible operating pressure
Connections
Safety valve
Dimensions
Length
Width
Height
Height with DHW cylinder installed below
the boiler
Gas connection
*3
Instantaneous water heater
Capacity DHW
Capacity
heating water
Hot and cold water connections
Permissible operating pressure
(DHW side)
Outlet temperature (adjustable)
Continuous DHW output
for heating DHW
from 10 ºC to 45 ºC
Drawing rate
Connection values
relative to max. output
with gas
with H
uB
3
Natural gas E
9.45 kWh/m
3
34.01 MJ/m
3
Natural gas LL
8.13 kWh/m
3
29.25 MJ/m
LPG
1279 kWh/kg
46.04 MJ/kg
*4
Flue gas values
Flue gas value group according to G 635/G 636
Temperature (at a return
temperature of 30 ºC)
at rated output
at partial load
Temperature (at a return
temperature of 60 ºC)
Mass flow rate
for natural gas
at rated output
at partial load
for LPG
at rated output
at partial load
Available draught
*1
Details to EN 677.
*2
If the gas supply pressure is higher than the maximum permissible value, install a separate gas governor upstream of the system.
*3
Minimum pressure of the cold water connection 1 bar.
*4
Calculation values for sizing the flue gas system to EN 13384.
Flue gas temperatures measured as gross values at 20 ºC combustion air temperature.
The details for partial load refer to an output of 30 % of rated output. Calculate the flue gas mass flow rate accordingly when the
partial load differs from that stated above (subject to the burner mode).
The flue gas temperature at a return temperature of 30 ºC is decisive for sizing the flue gas system.
The flue gas temperature at a return temperature of 60 ºC is used to determine the application range of flue pipes with maximum
permissible operating temperatures.
VITODENS
kW
kW
kW
mbar
mbar
*2
mbar
mbar
W
kg
litres
l/h
l/h
litres
bar
bar
R (fem. thread)
mm
mm
mm
mm
R (male thread)
litres
litres
G (male thread)
bar
ºC
kW
litres/h
litres/min
3
m
/h
3
m
/h
kg/h
ºC
ºC
ºC
kg/h
kg/h
kg/h
kg/h
Pa
mbar
Gas fired boiler
8.8 20.0
8.8 26.0
8.0 18.2
8.0 24.7
8.4 18.9
8.4 25.7
CE 0085 BO 0342
20
50
25.0
25.0
57.5
57.5
120
120
52
5.0
1 400
1 400
860
1 118
10
0.75
0.75
3
¾"
380
380
480
480
850
850
1 925
1 925
½"
2.00
2.72
2.32
3.16
1.48
2.01
G
/G
G
/G
52
51
52
55
32
78
32.3
42.0
14.0
14.0
35.7
46.4
15.4
15.4
100
100
1.0
1.2 Specification
Vitodens 200
Gas fired combi boiler
8.8 26.0
8.0 24.7
8.4 25.7
20
50
25.0
57.5
120
52
5.0
5.0
1 400
1 118
10
0.75
3
¾"
¾"
380
480
850
1 925
½"
½"
0.2
0.2
½"
38 57
590
3 8
2.72
3.16
2.01
G
/G
51
52
55
32
78
78
42.0
14.0
46.4
15.4
100
1.0
1.0
200
20
50
1
54
10
3
10
24
51
55
32
9