4.2 Design and sizing information for connection on the flue gas side
300
Max. total length of the flue pipe
Vitodens 300
Rated output (total)
Max. length of the total horizontal interconnecting pipe
System size 125 mm
System size 150 mm
Max. pipe length inside the duct
System size 125 mm
System size 150 mm
System size 200 mm
Max. total length of the flue pipe
System size 125 mm
System size 150 mm
System size 200 mm
*1
An eccentric expansion piece ∅ 125/150 mm or ∅ 150/200 mm is part of the standard delivery of the flue gas cascade.
The flue gas header concludes the
standard delivery. The inspection piece
and all other flue gas accessories should
be ordered for each individual system
(see flue gas system pricelist for the
Vitocrossal).
4
162
kW
kW
m
m
m
m
m
m
m
m
Note
Flue gas characteristics for individual
boilers can be transferred to the flue gas
system calculation (see specification).
2 × 49
2 × 66
3 × 49
98
132
147
3
3
4
9
27
27
18
12
*1
*1
30
30
22
3 × 66
4 × 66
198
264
4
5
18
10
26
25
22
15
*1
30
30
VITODENS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 300Vitodens 333Vitodens 343

Table of Contents