 Real-time monitor
Refer to page 136 for details of the monitor description.
Register
Description
40201
Output frequency/Speed
40202
Output current
*8
40203
Output voltage
*8
40205
Frequency setting value/Speed setting
40206
Running speed
40208
Converter output voltage
40209
Regenerative brake duty
Electronic thermal relay function
40210
load factor
40211
Output current peak value
40212
Converter output voltage peak value
40213
Input power
40214
Output power
40215
Input terminal status
40216
Output terminal status
40217
Load meter
40220
Cumulative energization time
40223
Actual operation time
40224
Motor load factor
40225
Cumulative power
*1
The setting depends on capacities. (01160 or less/01800 or more)
Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, : undetermined value)
*2
b15
Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, : undetermined value)
*3
b15
*4
When Pr.37 = "1 to 9998" or Pr. 144 = "2 to 10, 102 to 110," the unit is an integral value (one increment). (Refer to page 134)
*5
Option input terminal 1 monitor details (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0) -all terminals
are OFF when an option is not fitted
b15
X15
X14
X13
X12
*6
Option input terminal 2 monitor details (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0,
: undetermined value) -all terminals are OFF when an option is not fitted
b15
*7
Option output terminal monitor details (output terminal status of FR-A7AY/A7AR when the terminal is ON: 1, when the terminal is OFF: 0,
: undetermined value) -all terminals are OFF when an option is not fitted
b15
*8
The monitored values are retained even if an inverter fault occurs. Resetting will clear the retained values.
Increments
0.01Hz/1
*4 *8
0.01A/0.1A
0.1V
0.01Hz/1
*4
1r/min
0.1V
0.1%
0.1%
0.01A/0.1A
0.1V
0.01kW/0.1kW
0.01kW/0.1kW
*2
*3
0.1%
1h
1h
0.1%
1kWh
CS
RES
STOP
MRS
X11
X10
X9
RA3
RA2
Communication operation and setting
Register
Description
40250
Power saving effect
40251
Cumulative saving power
*1
40252
PID set point
40253
PID measured value
40254
PID deviation
40258
Option input terminal status 1
40259
Option input terminal status 2
40260
Option output terminal status
40264
PTC thermistor resistance
40267
PID measured value 2
*1
32-bit cumulative power
40277
(lower 16-bit)
*1
32-bit cumulative power
*1
40278
(upper 16-bit)
32-bit cumulative power
40279
(lower 16-bit)
32-bit cumulative power
40280
(upper 16-bit)
JOG
RH
RM
ABC2
ABC1
X8
X7
X6
X5
RA1
Y6
Y5
Increments
Variable
Variable
0.1%
0.1%
0.1%
*5
*6
*7
0.01k
0.1%
1kWh
1kWh
0.01kWh/
0.1kWh
0.01kWh/
0.1kWh
RL
RT
AU
STR
FU
OL
IPF
SU
X4
X3
X2
X1
Y4
Y3
Y2
Y1
*1
*1
b0
STF
b0
RUN
b0
X0
b0
DY
b0
Y0
4
237