Monitor display and monitor output signal
Types of Monitor
Increments
Power saving
effect
Variable
according
to
Cumulative saving
parameters
power
*6
PID set point
0.1%
PID measured
0.1%
value
PID deviation
0.1%
Input terminal
status
Output terminal
status
Option input
terminal status
Option output
terminal status
PTC thermistor
0.01k
resistance
PID measured
0.1%
value 2
PLC function
0.1%
output
BACnet reception
status
BACnet token pass
counter
BACnet valid
APDU counter
BACnet
communication
error counter
Terminal CA output
level
Terminal AM
output level
*1
Frequency setting to output terminal status on the PU main monitor are selected by "other monitor selection" of the parameter unit (FR-PU04, FR-PU07).
*2
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0. When
the operation panel (FR-DU07) is used, the time is displayed up to 65.53 (65530h) in the indication of 1h = 0.001, and thereafter, it is added up from 0.
*3
The actual operation time is not added up if the cumulative operation time before power supply-OFF is less than 1h.
*4
When using the parameter unit (FR-PU04/FR-PU07), "kW" is displayed.
*5
The setting depends on capacities. 01160 or less/01800 or more)
*6
Since the panel display of the operation panel is 4 digits in length, the monitor value of more than "9999" is displayed as "----".
*7
When the output current is less than the specified current level (5% of the rated inverter current), the output current is monitored as 0A. Therefore,
the monitored value of an output current and output power may be displayed as "0" when using a much smaller-capacity motor compared to the
inverter or in other instances that cause the output current to fall below the specified value.
138
Pr. 52 Parameter
Setting Value
PU main
DU LED
monitor
50
51
52
53
54
*1
55
*1
56
57
64
67
1
81
1
82
1
83
1
84
85
86
Pr. 54 (CA)
Full-scale
Pr. 158 (AM)
value of the
Parameter
terminal CA
Setting
and AM
Value
Inverter
50
capacity
100%/
52
C42 or C44
100%/
53
C42 or C44
100%/
67
C42 or C44
70
100%
85
20mA
(Pr. 54 only)
86
10V
(Pr. 158 only)
Description
Displays energy saving effect monitor
You can change the monitor to power
saving, power saving average value,
charge display and % display using
parameters.
(For details, refer to page 160.)
Displays the set point, measured value and
deviation during PID control
(For details, refer to page 264.)
Displays ON/OFF status of the input
terminal on the PU
(Refer to page 140 for DU display)
Displays ON/OFF status of the output
terminal on the PU
(Refer to page 140 for DU display)
Displays ON/OFF status of the input terminal
of the digital input option (FR-A7AX) on the
DU (Refer to page 140 for details)
Displays ON/OFF status of the output
terminal of the digital output option (FR-
A7AY) and relay output option (FR-A7AR)
on the DU (Refer to page 140 for details)
Displays the PTC thermistor resistance at
terminal 2 when PTC thermistor protection
is active.
(0.10k to 31.5k(Refer to page 100)
Displays the measured value
(For details, refer to page 264.)
Desired values can be output from terminal
CA and AM using the PLC function.
Refer to the FR-F700 PLC function
programming manual for details of the PLC
function.
Displays the reception status of BACnet
communication
(Refer to page 242 for details)
Displays the count of received token
Displays the count of valid APDU detection
Displays the count of communication error
Displays actual output current level of
terminal CA which is controlled by BACnet
communication
(Refer to page 242 for details)
Displays actual output voltage level of
terminal AM which is controlled by BACnet
communication
(Refer to page 242 for details)