Optional Accessories; Dimensional Drawing; Technical Data - FAAC J275 2K HA Manual

Table of Contents

Advertisement

OPTIONAL ACCESSORIES

Emergency lowering device
(solenoid valve)
Cover
J275 2K HA
Obstacle detection device
(pressure switch)
 3
8
 2 Technical data
Power supply voltage
Max power
Max force
Pump delivery
Lifting time
Lowering time
Ambient operating temperature
Ambient operating temperature (with optional heater)
Type of use
Bollard weight
Pit weight
Oil quantity
Oil type
Protection rating
Hydraulic control unit protection rating

Dimensional drawing

Thrust capacitor (pre-wired)
Impact resistance
Break-in resistance
Impact resistance (STAINLESS STEEL)
Break-in resistance (STAINLESS STEEL)
Break-in resistance (double configuration)
Continuous use time (ROT)
Load class (EN124)
3.8 DIMENSIONAL DRAWING
525
230 V ~ 50 Hz
575 W
2500 N
3 l/min
~ 8 s
~ 4.5 s
-15 °C - +55 °C
-25 °C - +55 °C
Intensive
160 kg
60 kg
1.5 l
FAAC HP OIL
IP56
IP67
See  4
16 μF - 400V
85 kJ
287 kJ
134 kJ
414 kJ
656kJ (M30)
110 min at 23°C
C250 (25 t)
 4
532208 - Rev.A

Hide quick links:

Advertisement

Table of Contents
loading