Optional Accessories; Dimensional Drawing; Technical Data - FAAC J275 HA 2K20 Translation Of The Original Instructions

Table of Contents

Advertisement

OPTIONAL ACCESSORIES

Emergency lowering device
(solenoid valve)
Cover
J275 HA 2K20
Obstacle detection device
(pressure switch)
 3
8
 2 Technical data
Power supply voltage
Max power
Max force
Pump delivery
Lifting time
Lowering time
Ambient operating temperature
Ambient operating temperature (with optional heater)
Type of use
Bollard weight
Pit weight
Cylinder height
Cylinder diameter
Oil quantity
Oil type
Protection rating
Hydraulic control unit protection rating
Dimensions
Thrust capacitor (pre-wired)
Continuous use time (ROT)
Load class (EN124)

3.8 DIMENSIONAL DRAWING

525
230 V ~ 50 Hz
575 W
2500 N
3 l/min
~ 8 s
~ 4.5 s
-15 °C to +55 °C
-40 °C to +55 °C
Intensive
160 kg
80 kg
800 mm
275 mm
1.5 l
FAAC HP OIL
IP56
IP67
See 4
16 μF - 400V
110 min at 23°C
C250 (25 t)
550
532270 - Rev.A
4

Advertisement