MASONRY FLUE INSTALLATION
A 'Lined Chimney' installation is used when the existing chimney condition is inadequate for an
Open Chimney' installation and uses a Rinnai Flexiliner (flexible) flue system:
IMPORTANT
FLFHA5FLEX - for heaters Pre 2012 * / FLEXLINER03 - for heaters Post 29/11/12 2012 #
Refer to the instruction sheet provided with this kit for installation details.
Flexible Chimney Liner
Appliance Adaptor
Total chimney height MUST NOT be less than 3 metres and flue cowl must terminate above the
chimney in accordance with AS/NZS 5601.
NOTE
The hearth surface must be flat and level to support the entire heater. If the heater is not properly
supported noise and vibration may result.
In a masonry fireplace, use a slurry of sand and cement to level the base as required.
In a masonry fireplace, use a slurry of sand and cement to level the base as required.
Rinnai
Chimney Plate
Mortar
Adaptor
Lined Chimney Installation
Approved Chimney Cowl
Minimum
200mm
Minimum
3m
19
FLUEING
RIBF25 OIM