Special Program Mode - Henny Penny EVOLUTION ELITE Series Operator's Manual

Reduced oil capacity open fryer
Table of Contents

Advertisement

C C h h a a p p t t e e r r 6 6 L L e e v v e e l l 2 2
P P r r o o g g r r a a m m m m i i n n g g
Used to access the following:

• Special Program Mode

• Clock Set
• Data Communication
• Heat Control
• Tech Mode
• Stats
• Filter Control
6 6 . . 1 1 S S p p e e c c i i a a l l P P r r o o g g r r a a m m M M o o d d e e
The Special Program Mode is used to set more detailed programming. Prior to
accessing individual program modes, see the following procedure.
Press and hold the program button
1 1 ) )
by "SP PROG" and "ENTER CODE" show in the display.
Enter code 1, 2, 3, and "SP-1" "TEMP" "FORMAT" show in the displays.
2 2 ) )
NOTE:
• If a bad code is entered, a tone sounds and "BAD CODE" shows on the
display. Wait a few seconds, the controls revert back to the cook mode, and
repeat the above steps.
• To exit from the Special Program Mode at any time, press and hold the
program button
Program Code
SP-1
Temperature: Degrees Fahrenheit or Celsius
SP-2
Language: English, Greek "EΛΛHNIKA", Russian "РУССКИИ",
Swedish "SVENSKA", German "DEUTSCHE", Portuguese "POR-
TUG.", Spanish "ESPANOL", or French "FRANCAIS".
SP-3
System Initialization (Factory Presets)
SP-4
Audio Volume (Loudness)
SP-5
Audio Tone (Frequency)
SP-6
Melt Cycle Selection - 1.LIQUID; 2.SOLID
for five seconds until "LEVEL 2" followed
for 2 seconds.
T T a a b b l l e e 6 6 - - 1 1 S S p p e e c c i i a a l l P P r r o o g g r r a a m m M M o o d d e e s s