Henny Penny EVOLUTION ELITE Series Operator's Manual page 39

Reduced oil capacity open fryer
Table of Contents

Advertisement

If filtering is not desired, press the "X" button and the AIF (Automatic Intermittent
5 5 ) )
Filter) is canceled. The blue light goes out and the controls return to normal
operation. The controls will suggest filtering after several more cook cycles.
NOTICE: If display shows "VAT EMTY" "YES NO", check that the drain is clear and
vat is empty. Press "✓" button and display shows "WASHING" followed by "FILLING".
NOTE: The WASH step of the first Autofilter on a new filter pad lasts an extra 45
seconds to "break in" the pad.
If the display shows "IS POT FILLED?" "YES NO", make sure vat is full and then
6 6 ) )
press "✓" button for yes and control returns to normal operation.
If the oil has not pumped back to the proper level in the vat during the AIF
7 7 ) )
process, press "X" button for "NO" and display shows "0:30" and counts down to
"0:00".
Display shows "IS POT FILLED?" "YES NO". Press "✓" button and control
8 8 ) )
returns to normal operation. Press "X" button and pump runs for another 30
seconds. You can try to fill the vat 3 times.
After trying to fill the vat 3 times without success, the controls then shows
9 9 ) )
"CHANGE FILTER PAD?" "YES NO". If changing the filter pad at this time,
press "✓" and change filter pad following the procedures in the
The Filter Pad , page
changed at a later time, press "✓" button and "CHANGE FILTER PAD?"
reminder shows 15 minutes later.
During the next AIF with a new filter pad, if the vat is not filled after 3 tries, the
1 1 0 0 ) )
display shows "FILTER SERVICE REQUIRED-SEE TROUBLESHOOTING
GUIDE".
If the "Service Required" message appears, then every 15 minutes the display
1 1 1 1 ) )
shows "FILTER PROBLEM FIXED? YES NO". If the problem has not been
fixed, press "X" button. Once the problem has been resolved, press "✓" and
controls return to normal operation.
NOTE: To help ensure the vat fills completely, make sure filter pan is cleaned at least
daily, filter pad is changed, make sure JIB is full and that "O" rings on the filter pan are
in good condition.
41. Controls return to normal operation. If filter pad is to be
3.14 Changing
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eeg-16xEeg-241Eeg-244Eeg-243Eeg-242

Table of Contents