6. Multi I/O modules
Module parameters: Reaction after short circuit/overload
Function no.
4828 + m * 64 + 1
Description
Determines after a short circuit in the sensor supply or the outputs whether the
power is to remain switched off or whether it is to be switched on again auto
matically.
Reaction after short circuit/overload
Bit
Description
0
Short circuit/overload in sensor supply (SCS)
1
Short circuit/overload at the outputs (SCO)
Values
0 = V
1 = V
Presetting:
Remark
With the setting V
required to restore power. Check which setting is necessary for reliable oper
ation of your system.
Detailed description under Diagnosis", Tab. 6/14.
Tab. 6/6:
Reaction after short circuit/overload
Festo P.BE−CPX−EA−EN en 0503c
/V
remains switched off
SEN
OUT
/V
switch on again
SEN
OUT
Bit 0: V
/V
SEN
OUT
Bit 1: V
/V
SEN
OUT
remains switched off", Power on/off or Set/Reset is
SEN/OUT
m = module number (0 ... 47)
switch on again
remains switched off
[Behaviour after]
[Behaviour after SCS]
[Behaviour after SCO]
[Leave switched off ]
[Resume]
6−11