Table 2-3
Option
Setting 1
Scanner
Press
Long Probe
Retest
Scan Timeout
ICT Timeout
Recontact Timeout
D/Stream Timeout
Setting 2
Jig Height
DUT Access
Board Align
Width
Scan on Fly
DSB RLS Chk
2-6
Settings
Description
Bypass – Skip the action.
Non-Bypass – Perform the action.
This is set via the testplan (except for the Press setting).
Time (in seconds) to wait for scan result from the controller
before triggering an error.
Time (in seconds) to wait for test result from the controller
before triggering an error.
Time (in seconds) to wait before retest.
Time (in seconds) to wait for DSB (Downstream Busy) signal
from downstream machine.
Note: Default timeout = 300 s; minimum 1 s; maximum 999 s.
Set the jig height to 75 mm, 85 mm or 100 mm.
For systems with optional DUT Access:
Enable or disable access to failed boards.
Whether to check if the board is seated correctly.
Enable or disable automatic conveyor width control.
Whether to scan barcode without stopping the board.
Downstream Busy signal release check.