Lam bda 465 Advanced Transm ission Holder
This instruction sheet describes the installation of this accessory which is used with the Lambda 465
Spectrophotometer.
Read these instructions before you install this accessory.
NOTE:
Contacting P erk inElm er
Supplies, replacement parts, and accessories can be ordered directly from PerkinElmer, using the part
numbers.
See our website:
http://perkinelmer.com
PerkinElmer's catalog service offers a full selection of high-quality supplies.
To place an order for supplies and many replacement parts, request a free catalog, or ask for information:
If you are located within the U.S., call toll free 1-800-762-4000, 8 a.m. to 8 p.m. EST. Your order will be
shipped promptly, usually within 24 hours.
If you are located outside of the U.S., call your local PerkinElmer sales or service office.
Features
Use for measuring the transmittance of various features of film, glass, and plate, etc.
User-convenient sampling
Adjustable fixing arms for the samples with various thickness
Height controller to meet sample features
Internal magnet for fixing sample
Figure 1 Lambda 465 Advanced Transmission Holder [P/N: N4104005]
I nstallation I nstructions
09931298C
PerkinElmer, 710 Bridgeport Avenue,
Shelton, CT 06484-4794, U.S.A
Produced in the USA.

Advertisement

loading

Summary of Contents for PerkinElmer Lambda 465

  • Page 1 09931298C Lam bda 465 Advanced Transm ission Holder I nstallation I nstructions This instruction sheet describes the installation of this accessory which is used with the Lambda 465 Spectrophotometer. Read these instructions before you install this accessory. NOTE: Contacting P erk inElm er Supplies, replacement parts, and accessories can be ordered directly from PerkinElmer, using the part numbers.
  • Page 2: Dimensions And Specifications

    Dimension (mm) 100 (H) X 80 (W) X 150 (L) Weight (kg) Max. Length : 300 x 300 Sample Size (mm) Max. Thickness : 70 Description Configuration of Advanced Transm ission Holder Figure 2 Lambda 465 Advanced Transmission Holder configuration...
  • Page 3: Installation

    09931298C I nstallation 1. Disassemble the existing cell holder. Figure 3 Location of screws 2. Install the advanced transmission holder by fastening the knob bolts. Figure 4 Fastening the bolts 3. Connect the communication cable and the power cord, and then turn on the power of the Lambda 465.
  • Page 4 09931298C Sam pling Proper Size Sam ple 1. Prepare a sample plate. Figure 5 Preparing a sample plate 2. Open the fixing arm and insert the sample. Figure 6 Opening the fixing arm...
  • Page 5 09931298C 3. Close the fixing arm to fix the sample. Figure 7 Closing the fixing arm on the sample 4. Adjust the sample loading height using the height controller depending on the sample size. Figure 8 Controlling the height M easurem ent : Start the sample measurement after warming up the system for at least 20 minutes.
  • Page 6 09931298C Select Transmittance mode (%T) in the Data Type and select OK. Place the air or reference plate on the sampling port and click Blank to measure blank. Insert sample in the advanced transmission holder and click Sample to measure sample.