Environmental Specifications

Table 17: Environmental Specifications
Specification
Operating Temperature
Nonoperational temperature
Non-operational temperature
(Transportation or Storage, or both)
Operational humidity
Non-operational humidity
Non-operational altitude
Operational mechanical shock
Non-operational mechanical shock
Cisco ASR 920-10SZ-PD and Cisco ASR-920-8S4Z-PD Aggregation Services Router Hardware Installation Guide
Environmental Specifications, on page 73
C H A P T E R
Value
–40º C to 65º C
Note
The temperature range will vary for supported SFP/SFP+
installed on the router. See the corresponding SFP/SFP+
documentation for more details.
40 to 158°F (-40 to 70°C)
-40°F (-40°C) for 72 hrs
158°F (70°C) for 72 hrs
Section 4.1.1.1 of GR-63 or Section 9.1 of ATIS-0600010.2007
104°F (40°C) and 95% RH for 96 hrs
Section 4.1.1.3 of GR-63 or Section 9.3 of ATIS-0600010.2007
5% to 95%, RH condensing (GR-3108, Class 3)
5% to 95% RH
15000 ft
Acceleration half sine 50 m/s^2, for 11msec. 100 shocks/surface (EN
300 019-2-4 V2.3.1)
Acceleration half sine 180 m/s^2, for 6msec. 100 shocks/surface.
(EN 300 019-2-2 V2.3.1)
7