Environmental Specifications
Specification
Operational vibration
Non-operational vibration
Cold start
Hot start
Non-operational Free-Fall Drop
Earthquake, Zone 4
Cisco ASR 920-10SZ-PD and Cisco ASR-920-8S4Z-PD Aggregation Services Router Hardware Installation Guide
74
Value
2.5-200 Hz with spectral break point of 0.1 [(m/s²)²]/Hz (0.001 g²/Hz)
at 2.5 - 5 Hz 6 db/octave and 100-200 Hz at -24 db/octave. (EN 300
019-2-4 V2.3.1)
5-200 Hz with spectral break point of 1.0 [(m/s²)²]/Hz (0.01 g²/Hz)
at 5 - 100 Hz -6 db/octave and 20-200 Hz at -24 db/octave. (EN 300
019-2-2 V2.3.1)
-40°F (-40°C)
149°F (65° C)
Drop the unpackaged sample 3.9" onto a rigid surface. Drop 1 face,
2 edges, and 2 corners. (ENG-339611.Rev2 [Test Method:
IEC-68-2-32])
Equipment complies with earthquake tests per sections 4.4.1 and
5.4.1 of GR-63 or ANSI TI-329 (GR-3108 Class 3)
Specifications
Need help?
Do you have a question about the ASR-920-8S4Z-PD and is the answer not in the manual?
Questions and answers