Installation instructions
U
phase: Trickle charge with reduced voltage
2
In this phase, the charging voltage is reduced in order to maintain the
battery charge for an unlimited period and counteract self-discharge.
Additionally connected consumers are supplied via the charger in this
phase without loading the battery.
Battery
Gel battery
Wet cell battery
7
Mounting
To mount the device, perform the following steps:
Choose a cool, dry and well-ventilated mounting site.
Do not mount the device directly next to or above batteries.
Optimum cooling is achieved by mounting the unit vertically on
a flat surface.
1.
Fasten the device with screws to the 4 lateral holes (5 mm Ø).
The device is mounted.
Model
12 V
12 V
Page 14 of 18
Mounting
Charge voltage
13.8 V
13.5 V