27
:SBUS<n> Commands
:SBUS<n>:SENT:DISPlay
Command Syntax
:SBUS<n>:SENT:DISPlay <base>
<base> ::= {HEX | DECimal | SYMBolic}
The :SBUS<n>:SENT:DISPlay command specifies the number base used by the
decoder. The chosen base is used for the data nibbles in Raw decode format, the
defined Signals in the other formats, and for the data field of the Serial Messages.
This selection is used for both the Lister and the decode line displays.
When SYMBolic is selected, Fast Channel Signals display a calculated physical
value based on the specified multiplier and offset:
• PhysicalValue = (Multiplier * SignalValueAsUnsignedInteger) + Offset
When SYMBolic is selected, the CRC and Slow Channel information is displayed in
hex.
Query Syntax
:SBUS<n>:SENT:DISPlay?
The :SBUS<n>:SENT:DISPlay? query returns the SENT decode number base
setting.
Return Format
<base><NL>
<base> ::= {HEX | DEC | SYMB}
See Also
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
882
(see
page
1368)
":SBUS<n>:SENT:CLOCk"
":SBUS<n>:SENT:CRC"
":SBUS<n>:SENT:FORMat"
":SBUS<n>:SENT:IDLE"
":SBUS<n>:SENT:LENGth"
":SBUS<n>:SENT:PPULse"
":SBUS<n>:SENT:SIGNal<s>:DISPlay"
":SBUS<n>:SENT:SIGNal<s>:LENGth"
":SBUS<n>:SENT:SIGNal<s>:MULTiplier"
":SBUS<n>:SENT:SIGNal<s>:OFFSet"
":SBUS<n>:SENT:SIGNal<s>:ORDer"
":SBUS<n>:SENT:SIGNal<s>:STARt"
":SBUS<n>:SENT:SOURce"
":SBUS<n>:SENT:TOLerance"
":SBUS<n>:SENT:TRIGger"
":SBUS<n>:SENT:TRIGger:FAST:DATA"
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
on page 880
on page 881
on page 884
on page 886
on page 887
on page 888
on page 890
on page 891
on page 893
on page 895
on page 897
on page 899
on page 901
on page 902
on page 903
on page 905
Need help?
Do you have a question about the InfiniiVision M9241A and is the answer not in the manual?