:MEASure:VMAX

Command Syntax
:MEASure:VMAX [<source>]
<source> ::= {CHANnel<n> | FUNCtion<m> | MATH<m> | FFT | WMEMory<r>}
<n> ::= 1-2 or 1-4 (# of analog channels) in NR1 format
<m> ::= 1 to (# math functions) in NR1 format
<r> ::= 1 to (# ref waveforms) in NR1 format
The :MEASure:VMAX command installs a screen measurement and starts a
maximum vertical value measurement. If the optional source parameter is
specified, the current source is modified.
Query Syntax
:MEASure:VMAX? [<source>]
The :MEASure:VMAX? query measures and outputs the maximum vertical value
present on the selected waveform.
Return Format
<value><NL>
<value> ::= maximum vertical value of the selected waveform in
See Also
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
(see
page
1368)
NR3 format
"Introduction to :MEASure Commands"
":MEASure:SOURce"
on page 505
":MEASure:VMIN"
on page 522
":MEASure:VPP"
on page 523
":MEASure:VTOP"
on page 526
:MEASure Commands
on page 459