:SBUS<n>:A429:BASE
Command Syntax
:SBUS<n>:A429:BASE <base>
<base> ::= {BINary | HEX}
The :SBUS<n>:A429:BASE command selects between hexadecimal and binary
display of the decoded data.
The BASE command has no effect on the SDI and SSM fields, which are always
displayed in binary, nor the Label field, which is always displayed in octal.
Query Syntax
:SBUS<n>:A429:BASE?
The :SBUS<n>:A429:BASE? query returns the current ARINC 429 base setting.
Return Format
<base><NL>
<base> ::= {BIN | HEX}
Errors
•
See Also
•
•
•
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
(see
page
1368)
"-241, Hardware missing"
"Introduction to :SBUS<n> Commands"
":SBUS<n>:MODE"
on page 737
":SBUS<n>:A429:FORMat"
on page 1309
on page 733
on page 746
27
:SBUS<n> Commands
741
Need help?
Do you have a question about the InfiniiVision M9241A and is the answer not in the manual?