H. PROGRAM LOCATION 05 (PL05)
LO Temp
Temperature Decrease
LO Temp
Summary: LO Temp is programmable from a minimum of 100° F to a maximum of 190° F in ten-degree increments
or from a minimum of 38° C to a maximum of 88° C in five-degree increments.
For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a
minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to
a maximum of 77° C in five-degree increments.
For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable from
a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C
to a maximum of 71° C in five-degree increments.
Refer to Section V for instructions
on entering program locations.
PL05
Perm Press
LO°F
(Wait 3-Seconds)
120F
Perm Press
Automatically goes into PL06
Program without PL06 Display Mode
Continued on next page
39
Location to be viewed/changed.
Press "Perm Press" key.
Display will read "LO°F," LO Temp
status for 3-seconds and then the
actual temperature programmed.
If no changes, press "Perm Press"
key otherwise press "HI" or "LO"
keys and then "Perm Press" key.
Temperature Increase
HI Temp