Advertisement

Quick Links

Installation/Operator Manual
! ! ! ! !
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
● ● ● ● ●
Do not try to light any appliances.
● ● ● ● ●
Do not touch any electrical switch;
do not use any phone in your
building.
● ● ● ● ●
Clear the room, building or area of
all occupants.
● ● ● ● ●
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
● ● ● ● ●
supplier, call the fire department.
– Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
AD-22 / ML-22
Telephone: +1 (269) 923-3000 / Fax: +1 (508) 678-9447
e-mail: mdl-service@whirlpool.com / www.adclaundry.com
! ! ! ! !
AVERTISSEMENT:
RISQUE D'INCENDIE OU D'EXPLOSION
Le non-respect des avertissements de
sécurité pourrait entraîner des blessures
graves, la mort ou des dommages
matériels.
– N'entreposer pas et n'utilisez pas
d'essence ni d'autres vapeurs ou liquides
inflammables dans le voisinage de cet
appareil ou de tout autre appareil.
– QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ
● ● ● ● ●
Ne tentez pas d'allumer d'appareil.
● ● ● ● ●
Ne touchez à aucun interrupteur. Ne
vous servez pas des téléphones se
trouvant dans le bâtiment où vous
vous trouvez.
Évacuez la pièce, le bâtiment ou la zone.
● ● ● ● ●
● ● ● ● ●
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
● ● ● ● ●
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
– L'installation et l'entretien doivent être
assurés par un installateur ou un service
d'entretien qualifié ou par le fournisseur
de gaz.
American Dryer Corporation
88 Currant Road, Fall River MA 02720-4781 USA
ADC Part No. 113279- 9

Advertisement

Table of Contents
loading

Summary of Contents for ADC ML-22

  • Page 1 American Dryer Corporation 88 Currant Road, Fall River MA 02720-4781 USA Telephone: +1 (269) 923-3000 / Fax: +1 (508) 678-9447 e-mail: mdl-service@whirlpool.com / www.adclaundry.com ADC Part No. 113279- 9...
  • Page 2 Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory, you can FAX your order to ADC at +1 (508) 678-9447 or telephone your order directly to the ADC Parts Department at +1 (269) 923-3000. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.
  • Page 3: Table Of Contents

    WARNING In the State of Massachusetts, the following Children should not be allowed to play on or installation instructions apply: near the dryer(s). Children should be ■ Installations and repairs must be performed by a supervised if near dryer(s) in operation. qualified or licensed contractor, plumber, or gas fitter qualified or licensed by the State of Massachusetts.
  • Page 4: Safety Precautions

    Safety Precautions ___________________ WARNING WARNING Do not use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber For your safety, the information in this manual must materials. Drying in a heated tumbler may damage be followed to minimize the risk of fire or explosion plastics or rubber and also may be a fire hazard.
  • Page 5 The operation of this appliance may affect the operation of other types of gas appliances, which take their air for safe combustion from the same room. If in doubt, consult the NOTES _____________________________________________________ appliance manufacturer(s). Use this dryer only for its intended purpose, drying fabrics. ____________________________________________________________ The “Cool Down”...
  • Page 6: Specifications

    Specifications _____________________________________________________________________ 9.98 kg MAXIMUM CAPACITY (DRY WEIGHT) 22 lb TUMBLER DIAMETER 25-3/4” 65.41 cm TUMBLER DEPTH 24-3/4” 62.87 cm TUMBLER VOLUME 7-1/2 cu ft 212.38 L TUMBLER/DRIVE MOTOR 1/3 hp 0.25 kW BLOWER/FAN MOTOR BLOWE R D RIV EN B Y TUMBLE R MOTOR DOOR OPENING (DIAMETER) 21-1/2”...
  • Page 7 Specifications _____________________________________________________________________ NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. 113279- 9 www.adclaundry.com...
  • Page 8: Installation Procedures

    Installation Procedures ______________ Unpacking / Setting Up ________________ Installation should be performed by competent professional Remove protective shipping material (i.e., plastic wrap and in accordance with local, state, and country codes. In the optional shipping box) from the dryer. absence of these codes, the installation must conform to applicable American National Standards: National Fuel Gas IMPORTANT: Dryer must be transported and handled in an Code ANSI Z223.1/NFPA 54 and National Electric Code ANSI/...
  • Page 9: Fresh Air Supply Requirements

    Domestic Type I A = 10-inches (25.4 cm) B = 6-inches (15.24 cm) EXAMPLE: For a bank of four dryers, two unrestricted openings measuring 10-inches by 6-inches (25.4 cm by 15.24 A = 6-inches (15.24 cm) B = 10-inches (25.4 cm) cm) are acceptable.
  • Page 10 IMPORTANT: Exhaust back pressure measured by a Vertical Venting manometer/magnehelic in the exhaust duct must be no When vertical dryer venting is used, the length of the ductwork less than 0 and must not exceed 0.6 in WC (1.5 mb). from the dryer to the outside exhaust outlet, must not exceed 12 feet (3.66 meters).
  • Page 11: Electrical Information

    IMPORTANT: No more than four dryers should be Each dryer should be connected to an independently connected to one main common duct. protected branch circuit. The dryer must be connected with copper wire only. Do not use aluminum wire, which could The illustration below shows the minimum cross-sectional cause a fire hazard.
  • Page 12 Electrical Service Specifications Grounding Gas Models Only A ground (earth) connection must be provided and installed in accordance with local, state, and national regulations or ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET) codes of the country of destination. In the absence of these codes, grounding must conform to applicable requirements IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME.
  • Page 13: Gas Information

    For CE Models Only IMPORTANT: The dryer and its individual shutoff valve must be disconnected from the gas supply piping system The means for disconnection from the supply must be during any pressure testing of that system at test incorporated into wiring having a minimum contact separation pressures in excess of 1/2 psig (3.5 kPa) for non-CE of 3.0 mm in all poles.
  • Page 14: Converting From One Family Of Gas To Another

    Heat Input / Gas Consumption / Orifice (Injector) Data (For Non-CE [European] and Non-AGA [Australia] Models Only) Gas Specifications for Non-CE and Non-AGA Approved Dryers** Nominal Supply Gross Burner Orifice Orifice Size Heating Value Pressure Heat Input Pressure (Injector) Type Quantity B tu /ft in WC...
  • Page 15 The following conversion allows the dryer to be operated with rating (data) label/plate. either propane, butane, or other liquefied petroleum gases. The use of gas valve kit (ADC P/N 140414) disables the CE Dryers internal regulator of the gas valve. Therefore, the gas supply is ungoverned and an external regulator must be provided at Affix new data plate label that came with the conversion kit.
  • Page 16: Preparation For Operation / Start-Up

    (refer to the illustration on page 15). adjustment screw (under vent cap). Remove spring 60 Hz dryers: Install pressure tap and attach manometer (refer under screw and replace with spring from kit (ADC P/N to the illustration on page 15). 140415). Replace regulator adjustment screw.
  • Page 17: Preoperational Test

    • Be sure all back panels (guards) and electric box covers Tumbler Coating are in place. The tumbler is treated with a protective coating. We suggest • Be sure the service doors are closed and securely in dampening old garments or cloth material with a solution of place.
  • Page 18: Shutdown Instructions

    NOTE: Be sure to include the installation date when Shipping charges are not the responsibility of ADC. All returns returning the warranty card(s). should be “prepaid” to the factory. Any “C.O.D.” or “COLLECT”...
  • Page 19: Routine Maintenance

    IMPORTANT: No replacements, credits, or refunds will be NOTE: To prevent damage, avoid cleaning and/or touching issued if the claim cannot be processed due to insufficient ignitor/flame-probe assembly. information. The party filing the claim will be notified in writing, either by “FAX” or “CERTIFIED MAIL – Return Every 6 Months Receipt Requested,”...
  • Page 20: Data Label Information

    Data Label Information _______________ CE Label Standard Label When contacting ADC, the information on the data label is required to ensure proper service/parts assistance. The data label is located at the upper left rear of the dryer behind the back guard.
  • Page 21 NOTES __________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ 113279- 9 www.adclaundry.com...
  • Page 22 ADC Part No. 113279 9 - 06/16/22...

This manual is also suitable for:

Ad-22

Table of Contents