Installation Procedures ______________

Installation should be performed by competent technicians in
accordance with local and state codes. In the absence of
these codes, the installation must conform to applicable
American National Standards: ANSI.Z223.1-LATEST EDITION
(National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST
EDITION (National Electrical Code) or in Canada, the
installation must conform to Canadian Standards: CAN/CGA-
B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P.
Gas) or LATEST EDITION (for General Installation and Gas
Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA
C22.1-1990 or LATEST EDITION (for Electrical Connections).

Unpacking / Setting Up _______________

Remove protective shipping material (i.e., plastic wrap, and/
or optional shipping box) from dryer.
The dryer can be moved to its final location while still attached
to the pallet or with the pallet removed. To unpallet the dryer,
locate and remove the four bolts securing the base of the dryer
to the wooden pallet. Two are inside the lower back guard at
the rear base and two are located at the front base. To remove
the bolt located in the front, remove the lint door. Once the
bolts are removed, slide the dryer off the pallet.
With the pallet removed, to make it easier to slide the dryer
into its final position, slightly lower all four leveling legs, so
that the dryer will slide on the legs instead of the base frame.
The dryer is equipped with four leveling legs, one at each
corner of the dryer base.
The dryer should be level side-to-side and front-to-rear.

Location of the Dryer _________________

Before installing the dryer, be sure the location conforms to
local codes and ordinances. In the absence of such codes or
ordinances the location must conform with the National Fuel
Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the
installation must conform to applicable Canadian Standards:
CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-
M91 (L.P. Gas) or LATEST EDITION (for General Installation
and Gas Plumbing).
The dryer must be installed on a sound level floor capable of
supporting its weight. Carpeting must be removed from the
floor area that the dryer is to rest on.
IMPORTANT: "The dryer must be installed on
noncombustible floors only."
The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather.
The dryer is for use in noncombustible locations.
The dryer must be installed with provisions for adequate air
supply as noted in this manual (refer to Fresh Air Supply
Requirements section).
Clearance provisions must be made from noncombustible
construction as noted in this manual (refer to Dryer Enclosure
Requirements section).
Provisions must be made for adequate clearances for servicing
and for operation as noted in this manual (refer to Dryer
Enclosure Requirements section).
113019 - 7
Dryer must be exhausted to the outdoors in an area where
correct exhaust venting can be achieved as noted in this
manual (refer to Exhaust Requirements section).
Dryer must be located in an area where correct exhaust venting
can be achieved as noted in this manual (refer to Exhaust
Requirements section).
IMPORTANT: Dryer must be installed in a location/
environment, which the ambient temperature remains
between 40° F (4.44° C) and 130° F (54.44° C).

Dryer Enclosure Requirements _______

Bulkheads and partitions should be made of non-combustible
materials and must be located a minimum of 12-inches (30.48
cm), 18-inches (45.72 cm) or more is recommended for ease
of installation, maintenance, and service, above the dryer outer
top, except along the front of the dryer, which may be closed
in if desired. The clearance between the bulkhead header
and the dryer must be a minimum of 4-inches (10.16 cm) and
must not extend more than 4-inches (10.16 cm) to the rear of
the front.
IMPORTANT: If the dryer is installed in a closet type
enclosure there must be no other fuel burning appliance
installed in the same closet.
Dryers may be positioned sidewall to sidewall. However, a
1/16" (1.5875 mm) minimum allowance must be made for
opening and closing of the control door and the lint door. It is
suggested that the dryer be positioned about 2 feet (0.61
meters) away from the nearest obstruction for ease of
installation, maintenance, and service (to be measured from
the back guard). Refer to the illustration below for details.
Clearances shown are minimum dimensions to nearest
combustible materials.
NOTE A: 12-inch (30.48 cm) minimum, 18-inches (45.7 cm) is suggested for
ease of maintenance.
NOTE B: 12-inch (30.48 cm) minimum, 24-inches (61.0 cm) is suggested for
ease of maintenance.
NOTE: Fresh air considerations are important for proper
and efficient operation.
www.adclaundry.com
7