Advertisement

Quick Links

AD-222 / ML-222
Installation/Operator Manual
! ! ! ! !
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
● ● ● ● ●
Do not try to light any appliances.
● ● ● ● ●
Do not touch any electrical switch;
do not use any phone in your
building.
● ● ● ● ●
Clear the room, building or area of
all occupants.
● ● ● ● ●
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
● ● ● ● ●
If you cannot reach your gas
supplier, call the fire department.
– Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
! ! ! ! !
AVERTISSEMENT:
RISQUE D'INCENDIE OU D'EXPLOSION
Le non-respect des avertissements de
sécurité pourrait entraîner des blessures
graves, la mort ou des dommages
matériels.
– N'entreposer pas et n'utilisez pas
d'essence ni d'autres vapeurs ou
liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
– QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ
● ● ● ● ●
Ne tentez pas d'allumer d'appareil.
● ● ● ● ●
Ne touchez à aucun interrupteur. Ne
vous servez pas des téléphones se
trouvant dans le bâtiment où vous
vous trouvez.
● ● ● ● ●
Évacuez la pièce, le bâtiment ou la zone.
● ● ● ● ●
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
● ● ● ● ●
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
– L'installation et l'entretien doivent être
assurés par un installateur ou un service
d'entretien qualifié ou par le fournisseur
de gaz.
American Dryer Corporation
88 Currant Road, Fall River MA 02720-4781 USA
Telephone: +1 (269) 923-3000 / Fax: +1 (508) 678-9447
e-mail: mdl-service@whirlpool.com / www.adclaundry.com
ADC Part No. 112217-5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ML-222 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADC ML-222

  • Page 1 AD-222 / ML-222 Installation/Operator Manual ! ! ! ! ! ! ! ! ! ! WARNING: AVERTISSEMENT: FIRE OR EXPLOSION HAZARD RISQUE D’INCENDIE OU D’EXPLOSION Failure to follow safety warnings exactly Le non-respect des avertissements de could result in serious injury, death or sécurité...
  • Page 2 Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory, you can FAX your order to ADC at +1 (508) 678-9447 or telephone your order directly to the ADC Parts Department at +1 (269) 923-3000. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.
  • Page 3: Table Of Contents

    IMPORTANT In the State of Massachusetts, the following You must disconnect and lockout the electric supply installation instructions apply: and the gas supply or the steam supply before any ■ Installations and repairs must be covers or guards are removed from the machine to performed by a qualified or licensed allow access for cleaning, adjusting, installation, or contractor, plumber, or gas fitter qualified...
  • Page 4: Safety Precautions

    Safety Precautions ____________________ WARNING WARNING Do not use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber For your safety, the information in this manual must materials. Drying in a heated tumbler may damage be followed to minimize the risk of fire or explosion plastics or rubber and also may be a fire hazard.
  • Page 5 IMPORTANT: The dryer must be installed in a location/ environment, which the ambient temperature remains NOTES _____________________________________________________ between 40° F (4.44° C) and 130° F (54.44° C). ____________________________________________________________ The operation of this appliance may affect the operation of other types of gas appliances, which take their air for safe ____________________________________________________________ combustion from the same room.
  • Page 6: Specifications

    Specifications _____________________________________________________________________ 9.98 kg MAXIMUM CAPACITY 22 lb (DRY WEIGHT) PER POCKET TUMBLER DIAMETER 25-3/4” 65.41 cm 62.86 cm TUMBLER DEPTH 24-3/4” 212.38 L TUMBLER VOLUME 7-1/2 cu ft PER POCKET TUMBLER/DRIVE MOTOR 1/3 hp 0.25 kW PER POCKET BLOWER/FAN MOTOR BLOWER DRIVEN BY TUMBLER MOTOR PER POCKET DOOR OPENING...
  • Page 7 Specifications _____________________________________________________________________ NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. 112217 - 5 www.adclaundry.com...
  • Page 8: Installation Procedures

    Installation Procedures ______________ The dryer can be moved to its final location while still attached to the skid or with the skid removed. Installation should be performed by competent professional With the skid removed, use caution and assure all four in accordance with local, state, and country codes.
  • Page 9: Fresh Air Supply Requirements

    If a closet door is installed: unobstructed air openings are Allowances must be made for remote or constricting required. The air openings shall be located 3-inches passageways or where dryers are located at high altitudes (7.62 cm) from the lower opening (above floor level) and or predominantly low pressure areas.
  • Page 10 NOTE: As per the National Fuel Gas Code, “Exhaust ducts The length of the ductwork from the dryer to the outside for type 2 clothes dryers shall be constructed of sheet exhaust outlet, must not exceed 12 feet (3.66 meters). The metal or other noncombustible material.
  • Page 11: Electrical Information

    Electrical Information ________________ CAUTION: This unit has two power cords. Connect each plug to a receptacle that is connected to an Electrical Requirements individual branch circuit. Unplug both cords before moving or servicing this appliance. All electrical connections must be made by a properly licensed and competent electrician.
  • Page 12: Gas Information

    Electric Models Only Electrical Connections All electrically heated dryers must be connected to the A wiring diagram is located behind the control panel for electric service shown on the dryer’s data label. The connection data. connecting wires must be properly sized to handle the rated If local codes permit, power to the dryer can be made by the current.
  • Page 13 Piping / Connections IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements stipulated in this The dryer is provided with two 3/8” N.P.T. inlet pipe manual, can result in personal injury and improper connections (1 for each tumbler) at the rear of the dryer. If a operation of the dryer.
  • Page 14: Converting From One Family Of Gas To Another

    (injector). This orifice (injector) is made gases. The use of gas valve kit (ADC P/N 140414) disables of brass, which is easily damaged. the internal regulator of the gas valve. Therefore, the gas supply is ungoverned and an external regulator must be Reinstall the burner tube onto the burner base.
  • Page 15 Unregulated Gas Valve adjustment screw (under vent cap). Remove spring under screw and replace with spring from kit (ADC P/N Regulate (govern) gas externally (refer to “Supply Pressure” 140415). Replace regulator adjustment screw.
  • Page 16: Preparation For Operation / Start-Up

    Preparation for Operation / Start-Up__ Gas Pressure Adjustment Disconnect electrical power to the dryer. The following items should be checked before attempting to operate the dryer: IMPORTANT: The following procedures must be • Read all “CAUTION,” “WARNING,” and “DIRECTION” performed on both top and bottom tumblers. labels attached to the dryer.
  • Page 17: Preoperational Instructions

    Electrical Dryers NOTE: The dryer can be stopped at any time by opening the main door or the lint door. Check to ensure that electric oven/contactor assembly is activating. When the programmed drying time has expired, the non- coin microprocessor controller (computer) will proceed into Safety Related Circuits the Cool Down Cycle.
  • Page 18: Warranty

    Clean any lint accumulation in and around the motor(s) Shipping charges are not the responsibility of ADC. All casing opening. returns should be “prepaid” to the factory. Any “C.O.D.” or “COLLECT” returns will not be accepted.
  • Page 19: Data Label Information

    Complete an operational check of all safety devices (lint door/drawer switch, door switches, sail switch, and hi-limit thermostats). When contacting ADC, the information on the data label is required to ensure proper service/parts assistance. The Data Label Information ________________ data label is located at the upper left rear of the dryer behind the back guard.
  • Page 20 ADC Part No. 112217 5 - 06/17/22...

This manual is also suitable for:

Ad-222

Table of Contents