Program Location 04 (Pl04) - ADC Gas Electric Steam AD-26 User Manual

Phase 5 coin microprocessor controller
Table of Contents

Advertisement

G. PROGRAM LOCATION 04 (PL04)
HI Temp cool down temperature/time
Continued from F.
Temperature Decrease
LO Temp
Time Decrease
LO Temp
Proceed to next location
Summary: Cool down temperature is programmable from a minimum of 70° F to a maximum of 190° F in ten
degree increments or from a minimum of 21° C to a maximum of 88° C in five-degree increments.
For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a
minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to
a maximum of 77° C in five-degree increments.
For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable from
a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C
to a maximum of 71° C in five-degree increments.
Cool down is programmable from 0 to 9 minutes.
Refer to Section V for instructions
on entering program locations.
PL04
Perm Press
HICd
(Wait 3-Seconds)
·
·
100
2
Perm Press
·
100
2
Perm Press
PL05
to be changed
Location to be viewed/changed.
Press "Perm Press" key.
Display will read "HICd," HI Temp
cool down status for 3-seconds and then
the actual temp and time programmed.
If no change press "Perm Press" key twice,
otherwise press "HI" or "LO" keys and
then "Perm Press" key.
Temperature Increase
HI Temp
Time Increase
HI Temp
To exit program mode,
open program switch