Installation Procedures; Location Requirements; Unpacking / Setting Up; Dryer Enclosure Requirements - ADC ML-222 Operator's Manual

Table of Contents

Advertisement

Installation Procedures ______________

Installation should be performed by competent professional
in accordance with local, state, and country codes. In the
absence of these codes, the installation must conform to
applicable American National Standards: National Fuel Gas
Code ANSI Z223.1/NFPA 54 and National Electric Code ANSI/
NFPA 70, or in Canada, the installation must conform to
applicable Canadian Standards: Natural Gas and Propane
Installation Code CSA B149.1 and Canadian Electric Code
CSA C22.1.

Location Requirements ______________

Before installing the dryer, ensure the location conforms to
local codes and ordinances. In the absence of such codes
or ordinances the location must conform with National Fuel
Gas Code ANSI Z223.1/NFPA 54, or in Canada, the
installation must conform to applicable Canadian Standards:
Natural Gas and Propane Installation Code CSA B149.1.
The dryer must be installed on a sound level floor capable
of supporting its weight. Carpeting must be removed from
the floor area that the dryer is to rest on.
The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather.
Provisions for adequate air supply must be provided as
noted in this manual (refer to Fresh Air Supply Requirements
section).
Clearance provisions must be made from combustible
construction as noted in this manual (refer to Dryer
Enclosure Requirements section).
Provisions must be made for adequate clearances for
servicing and for operation as noted in this manual (refer to
Dryer Enclosure Requirements section).
The dryer must be installed with a proper exhaust duct
connection to the outside as noted in this manual (refer to
Exhaust Requirements section).
The dryer must be located in an area where correct exhaust
venting can be achieved as noted in this manual (refer to
Exhaust Requirements section).
IMPORTANT: The dryer should be located where a
minimum amount of exhaust ducting will be necessary.
The dryer must be installed with adequate clearance for air
openings into the combustion chamber.
CAUTION: This dryer produces combustible lint and
must be exhausted to the outdoors. Every 6 months,
inspect the exhaust ducting and remove any lint
buildup.
IMPORTANT: The dryer must be installed in a location/
environment, which the ambient temperature remains
between 40° F (4.44° C) and 130° F (54.44° C).

Unpacking / Setting Up _______________

Remove protective shipping material (i.e., plastic wrap and
optional shipping box) from the dryer.
IMPORTANT: Dryer must be transported and handled in
an upright position at all times.
8
The dryer can be moved to its final location while still
attached to the skid or with the skid removed.
With the skid removed, use caution and assure all four
leveling legs are fully retracted, if the dryer is to be slid into
its final position.
Leveling Dryer
The dryer is equipped with 4 leveling legs, 1 at each corner
of the base. For optimum performance the dryer should be
level front-to-back and side-to-side.

Dryer Enclosure Requirements ______

Bulkheads
noncombustible material.
NOTE: Allowances must be made for opening the control
door.
A
The requirement to allow the door to open completely is
28-inches (71.12 cm).
B
A minimum overhead clearance of 6-inches (15.24 cm) is
required.
C
Dryer should be positioned a minimum of 12-inches (30.48 cm)
away from the nearest obstruction. 24-inches (60.96 cm) is
recommended for ease of installation, maintenance, and
service.
D
1/16" (1.5875 mm) minimum is required.
E
Flooring should be level or below dryer cabinet for ease of
removing panels during maintenance.
F
Dryers may be positioned sidewall to sidewall, however a 1/
16" (1.5875 mm) minimum allowance must be made for the
opening and closing of the control door, along with the removal
of panels during maintenance.
A = 10" (25.4 cm)
B = 12" (30.48 cm)
EXAMPLE: Two unrestricted openings measuring 10-inches
by 12-inches (25.4 cm by 30.48 cm) are acceptable.
American Dryer Corp.
and
partitions
should
be
made
of
112217 - 5