Figure 2-11 Disabling and Enabling the Link Integrity Test

2.5.2.2 Installation
1. Remove the filler panel (if any) covering the SBus slot opening.
Retain the screws to attach the SBus card to the back panel, unless the card
has a wide connector or connectors. See the SBus card installation manual to
verify the specific connector type.
2. Unlock the two standoffs for the slot.
Pull up the tip of a standoff to unlock it, as shown in Figure 2-3.
3. Take the SBus card out of the protective packaging and inspect the SBus
connector for damaged pins.
4. Guide the SBus card face plate under the springfingers and against the
rear face of the back panel.
Refer back to Figure 2-6. The I/O connectors of the card should be visible
through opening in the back panel.
5. Hold the card by the edges nearest the SBus connector and rest the card
lightly on the two standoffs.
6. Firmly but gently press the card straight down until the connector is fully
seated. At the same time, align the connector and socket, pushing the card
toward the system board back panel.
Caution – Do not rock the card onto the socket; the SBus connector housing
!
may break.
7. Press down on each corner of the card to ensure that the corner rests fully
on the flange of the standoff.
8. Press down on the tip of each standoff to lock the card in place.
Removing and Replacing System Boards and Assemblies
Link Integrity Test
2
Enabled
1
2
2-11