7.2.13 Module 12: Status - Leuze electronic BPS 34 Technical Description

Barcode positioning system for the profibus db
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Leuze
electronic

7.2.13 Module 12: Status

Description
This module defines various items of status information from the BPS34.
Parameter
none
Input Data
Input data
Measure-
ment error
Range
status
Limit value
status 1
Limit value
status 2
Table 7.20:
Input data length: 1byte consistently
Output Data
none
Leuze electronic
Description
[Measurement Value Preparation]
Indicates that no valid integration
value could be determined.
[Measurement Value Acquisition]
Indicates that measurement range
has been exceeded
[Measurement Value Monitoring]
Indicates that limit value 1 has
been exceeded or undershot.
[Measurement Value Monitoring]
Indicates that limit value 2 has
been exceeded or undershot.
Input data for Module 12
Address Data
0.0
0.1
0.4
0.5
BPS 34
Value Range
Init
Type
Value
0 : OK
Bit
1 : Integra-
0
tion error
0 : OK in the
measure-
ment range
Bit
0
1 : Measure-
ment range
exceeded
0: Not
Bit
exceeded
0
1: Exceeded
0: Not
Bit
exceeded
0
1: Exceeded
Profibus
Unit
-
-
-
-
41