Profibus
7.2.18 Module 17: Dynamic limit value 2
Description
The limit value function compares the position value with a stored position. If the limit value
is exceeded or undershot, an action is triggered and a status is set.
The limit value is defined using output data from the Profibus master.
Parameter
Parameter
Limit value
mode 2
Switching
mode 2
Hysteresis 2
Table 7.28:
Parameter length: 4bytes
Input Data
none
Output Data
Output Data
Limit value 2
Table 7.29:
Output data length: 4 byte consistently
46
Description
Parameter activates
limit value checking.
Condition for signal
change
Rel. offset of
switching point
Parameters for Module 17
Description
Limit value which is
compared to current
output position.
Output data for Module 17
Rel.
Data Type
address
0
UNSIGNED 8
1
UNSIGNED 8
2
UNSIGNED 16 0-65535
Address Data Type
0
SIGNED 32
BPS 34
Leuze
electronic
Value Range Standard Unit
0: Off
0
1: On
0: Exceeded
1: Under-
0
shot
0
Value Range
Init
Value
-10 000 000 ...
0
10 000 000
Leuze electronic
-
mm
Unit
mm