7.2.15 Module 14: Static limit value 1

Description
The limit value function compares the position value with a position stored during parame-
terisation. If the limit value is exceeded or undershot, an action is triggered and a status is
set.
Parameter
Parameter
Limit value
mode 1
Switching
mode 1
Hysteresis 1
Limit
value 1
Table 7.24:
Parameter length: 8bytes
Input Data
none
Output Data
none
Leuze electronic
Description
Parameter activates
limit value checking.
Condition for signal
change
Rel. offset of switch-
ing point
Limit value which is
compared to current
output position.
Parameters for Module 14
Rel.
Data
address
Type
UNSIG-
0
NED 8
UNSIG-
1
NED 8
UNSIG-
2
NED 16
SIGNED
4
32
BPS 34
Value Range
Standard Unit
0: Off
0
1: On
0: Exceeded
0
1: Undershot
0-65535
0
-10 000 000 ...
0
10 000 000
Profibus
-
mm
mm
43