7.2.12 Module 11: Measurement Value Processing - Leuze electronic BPS 34 Technical Description

Barcode positioning system for the profibus db
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Profibus

7.2.12 Module 11: Measurement value processing

Description
The measurement value processing module integrates the acquired raw position data to
form a position value.
Parameter
Parameter
Integration
depth
Table 7.18:
Parameter length: 2bytes
Input Data
none
Output Data
Output Data
Count
direction
Table 7.19:
Output data length: 1byte consistently
40
Description
Number of consecutive
scans which are to be
used for position deter-
mination.
Parameters for Module 11
Description
Count direction for
position calculation
Output data for Module 11
Rel.
Data
address
Type
UNSIG-
0
NED 8
Address Data
Value Range
Type
0: normal
0.0
Bit
1: inverse
BPS 34
Leuze
electronic
Value Range Standard Unit
0 ... 255
8
Init
Value
0
Leuze electronic
Measure-
ments
Unit
-

Advertisement

Table of Contents
loading

Table of Contents