Installation
6.4.2
Connection of switching inputs and outputs
The BPS 34 is provided with a switching input and a switching output. The connection of the
switching inputs and outputs is carried out according to figure 6.6:
Figure 6.6: Connection diagram switching inputs and outputs BPS 34
Switching input
In the standard setting, you can reset output of the positioning data (preset) via the switching
input connection SWIN by connecting SWIN (pin 4) and VOUT (pin 1).
Switching output
The switching output connection between SWOUT (pin 2) and GND (pin 3) is normally open.
In the standard setting, SWOUT is closed in the case of a positioning error.
Notice!
You can configure the switching inputs and outputs according to your requirements by using
the modules 7
6.5
Disassembling, Packing, Disposing
Repacking
For later re-use, the device is to be packed so that it is protected against shocks and damp-
ness. Optimal protection is achieved when using the original packaging.
Notice!
Electrical scrap is a special waste product! Observe the locally applicable regulations re-
garding disposal of the product.
26
A
Sensor
max.
100 mA
(switching
input) and 8
Connector SW IN/OUT
4
SWIN
1
V OUT
2
SW OUT
3
GND
5
PE
1
V IN
3
GND IN
Connector PWR
(switching
output).
BPS 34
Leuze
electronic
Leuze electronic