Module 4: Dynamic Preset - Leuze electronic BPS 34 Technical Description

Barcode positioning system for the profibus db
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Leuze
electronic
Output Data
Output Data
Preset-Teach
Preset reset
Table 7.6:
7.2.5

Module 4: Dynamic preset

Description
This module is used to preset a value which the BPS is to output after an event (e.g. a 24V
level at the switching input) has occurred. The value is stored permanently in the BPS.
The preset value is defined using output data from the Profibus master.
Parameter
none
Input Data
none
Output Data
Output Data
Preset-Teach
Preset reset
Pre-set value
Table 7.7:
Output data length: 4bytes consistently
Leuze electronic
Description
Read-in of preset values
Resetting to default values,
deactivation of preset function
Output data for Module 4
Description
Read-in of preset
values
Resetting to default
values, switchover
of preset function
New position value
after preset
Output data for Module 4
Address Data
0.0
0.1
Address Data Type
0.0
Byte
0.1
Byte
1
UNSIGNED 32
BPS 34
Value Range
Type
0 = none
Byte
0->1 = Teach
0 = none
Byte
0>1 = reset
Value Range
Init
Value
0 = none
0
0->1 = Teach
0 = none
0
0>1 = reset
0 ...
0
10 000 000
Profibus
Unit
-
-
Unit
0
-
mm
31