Profibus
7.2.6
Module 5: Offset value
Description
The start value function adds an offset value to the scaled position value.
Parameter
Parameter Description
Offset
value
Table 7.8:
Parameter length: 4bytes
Input Data
none
Output Data
none
7.2.7
Module 6: Scaling
Description
The scaling function allows the position values to be converted to any unit of measurement.
To do this, the position is multiplied by the scaling factor.
Parameter
Parameter Description
Scaling
factor
Table 7.9:
Parameter length: 2bytes
Input Data
none
Output Data
none
32
Offset value added
to position value
Parameters for Module 5
Scaling factor used to
convert position
values
Parameters for Module 6
Rel.
Data Type
address
0
SIGNED 32
Rel.
Data Type
address
0
UNSIGNED 16 0-65535
BPS 34
Leuze
electronic
Value Range
Standard Unit
-10 000 000 ...
0
10 000 000
Value Range Standard Unit
1000
Leuze electronic
Scaled
units
Per
thou-
sand