Installation
Install the Airflow Plates in reverse order of removal, while referring to
Torque Specifications on page
Removing the Protective Covers from the Power Structures
You must remove the protective covers to gain access to the power
structures.
Removal
1. Remove power from the drive
page
3-3).
2. Move the Control Frame away from the power structure in the left-hand
enclosure
(Removing the Covers from the Power Structures on
page
3-15).
3. Remove the Airflow Plates
page
3-16).
4. On Power Structure 1, remove the four M5 Pozi-drive screws, which
secure the top and bottom protective covers to the main front protective
cover, then remove the top and bottom protective covers.
Note: you only need to remove the top and bottom covers to gain access
to the power terminals. You can remove the other covers without
removing the top and bottom ones
5. Remove the four M5 Pozi-drive screws, which secure the main front
protective cover to the drive, then remove the protective cover.
6. Remove the side protective covers.
3-1.
(Removing Power from the Drive on
(Removing the Airflow Plates on
Access Procedures