Installing the Rack Model in the Rack
Figure 9: Mounting the telescopic rail in the DataCenter Rack
The assemble telescopic rail and assembly bracket (HL) will be secured on the
front left support upright and on the support bracket.
Ê Using the supplied Allen key (No. 5) secure the end of the telescopic rail
without assembly bracket with two screws M5 (1) in the rack at the front left
support upright.
Please note that the guide nubs of the telescopic rail next to the spring nuts
must fit into the holes in the support upright.
Ê Secure the end of the telescopic rail assembled with the bracket (HL) with
two screws M4 (2) on the support bracket in the rack.
Note with the fact that the two mounting springs are inserted in the appro-
priate openings of the support bracket (see figure 8 on page 29).
Ê Adjust if necessary the length of the telescopic rail by using the oblong holes
of the assembly bracket (HL).
30
Installation
U41271-J-Z156-2-76