Installing the Rack Model in the Rack
Figure 7: Prepare the left telescopic rail
Ê Fasten the delivered assembly bracket HL on the rear end of the left
telescopic rail (1) with two screws M5x8 (2) and two hexagonal flange nuts
M5 (3) as shown in figure 7.
When mounting the left telescopic rail in the DataCenter Rack, the supplied
support bracket must first be mounted level with the device on the rear left
support upright.
Ê Refer to the assembly instructions in the Technical Manual for the
DataCenter Rack (see also "Related publications" on page 85).
Ê Using the mounting aid (stencil) mark the position of the attachment points
for the telescopic rails and for the server (front panel) on the support uprights
(five height units).
Refer to the information on the mounting aid.
Ê Mount the support bracket at the appropriate height on the left rear support
upright as described in the Technical Manual of the DataCenter Rack.