12. REMOVING TEST AND CALIBRATION EQUIPMENT

Use the following procedure to remove the test equipment after you completed the
adjustments or transfer of data.
• Unhook any load and move the boom into a safe position. Select a boom position
that allows you to disconnect the calibration equipment safely.
• Switch off the truck power. Disconnect the interface cable from the ribbon cable
connector [DB9]. Disconnect the interface cable from the Dataman S4 and store
cable and Dataman S4 in a secured and protected location. If you used the hand
terminal the interface cable remains connected to the hand terminal. Store cable
and hand terminal in a secured and protected location.
• Carefully disconnect the ribbon cable from the main board interface socket. Refer
to drawing 2.2.3 in section 2.2. Store cable in a secured and protected location.
• Carefully unplug the interface board. Use both hands to lift the board straight out of
the socket. The pins on the connector are extremely sensitive. Try to avoid bending
the pins. Use anti- static storage material to store the interface board. Refer to
drawing 2.2.1 in section 2.2.
• Remove jumper plug J2 if used for the hand terminal operation. Store the jumper
plug in a safe and secure area. The jumper plug is needed for whenever you
connect the hand terminal to the DS 50.
• Disconnect the external cables from the Mil type connectors.
TSM DS 50-003/REV.B/031-300-190-003/12-02-96
49