Overload Warning - PAT DS 50 Troubleshooting Manual

Overload warning system
Hide thumbs Also See for DS 50:
Table of Contents

Advertisement

DS50 TROUBLE SHOOTING MANUAL
10. TRANSFERRING EEPROM DATA
Transmit data to the EEPROM of the replacement unit:
Switch the truck power off (No power to DS 50)
Switch DATAMAN S4 off.
Connect the serial interface cable into the connector of the DATAMAN S4.
Connect the DB 9 connector of the interface cable into the DB 9 ribbon cable
connector of the DS 50 interface.
Switch DATAMAN S4 on and switch the truck power (DS 50 power) on.
Wait for minimum of 10 seconds.
The display will prompt twice (>) with two tones and the cursor flashes.
Press the white key >send<
the display indicates:
--> enter 00000,000FF using the key board
--> Press the >ENTER< key to confirm
The DATAMAN S4 checks the data and responds with a single tone and the
prompt.
At the completion of the transmission the DATAMAN S4 responds with:
After completion of the data transfer refer to section 2.1 and 2.2 to verify the
system function and calibration. Also refer to Trouble Shooting Manual 1 and 2 for
basic set up of the PAT DS 50 Overload Warning System.
TSM DS 50-003/REV.B/031-300-190-003/12-02-96
>SEND INTEL
00000,0FFFF (in example)
1 dual tones = DATA transmitted correctly
5 dual tones = Error in the data transmission
40
LEVEL 3

Advertisement

Table of Contents
loading

Table of Contents