DS50 TROUBLE SHOOTING MANUAL
LEVEL 3
9. ADJUSTING LOAD DISPLAY
continuation
Press the >CR< key to save the value. Display indicates >C-LOAD I= z <.
Note: z= the value entered previously.
Press the >CR< key to confirm and the display indicates >C-LOAD x= n<
Note: x= the next lower stored angle; n= the correction value entered previously for the x angle.
Do you want to
NO
enter correction factors
for lower boom
angles ?
YES
Press the key >K< to return to the start up menu.
Press the key >H< in the start up menu to verify
the load adjustment.
Hand terminal display indicates
>C-LOAD x= n:<. Enter the calculated
correction factor n for the x angle.
Refer to previous page reference of
stored angles. Press the key >CR< to
change to the new correction factor.
Repeat until you have entered all
previously calculated correction
factors for the stored angles.
The End
TSM DS 50-003/REV.B/031-300-190-003/12-02-96