DS50 TROUBLE SHOOTING MANUAL

2.2 THE HAND TERMINAL CONNECTION

In order to connect and use the hand terminal for data read-out or data adjustment
the DS 50 hardware must be prepared as follows:
• Switch the truck power off and remove the DS 50 central unit cover carefully as
described in manual level 1&2.
• Carefully insert the interface board into the interface board socket on the main
board.
CAUTION: The hole location in the interface board must match the hole location
on the main board. Otherwise you may damage the interface and
main board when powering the system up. Do not break, bend or skip
any pins on the interface board while you plug the board into the socket.
Refer to drawing 2.2.1 for installation of the interface board.
• The 'plug in' jumper J2 next to the interface board socket must be closed (mid & top
position of the 3 pin connector). Refer to drawing 2.2.2. Note the hand terminal will
not function with J2 not in the correct position.
• Plug the small ribbon cable adapter with the 10 conductor female plug into the male
interface connector on the main board next to the interface board socket.
• Plug the female DB 9 connector of the hand terminal cable into the male DB 9
connector at the other end of the ribbon cable. Refer to drawing 2.2.3 for cable
connection.
• Secure the ribbon and hand terminal cable with cable ties to avoid cable stress or
pulling off connections while operating the crane.
TSM DS 50-003/REV.B/031-300-190-003/12-02-96