DS50 TROUBLE SHOOTING MANUAL
10. TRANSFERRING EEPROM DATA
To read the EPROM with the calibration data back into the DATAMAN S4 follow the
procedure below. If the data is already in the memory of the DATAMAN S4 skip to
"Transmit data to the DS 50" in this section.
Read EPROM data into the DATAMAN S4
Switch the truck power off (No power to DS 50)
Disconnect the serial interface cable from the DB 9 ribbon cable connector of the
DS 50 interface.
Switch the DATAMAN S4 on.
Plug the EPROM with the calibration data into the DATAMAN S4 EPROM socket.
Refer to the user manual for correct insertion.
Press the green key >LOAD<
The display indicates:
if not
--> Enter >00000 - 07FFF=00000< on the last line and press >ENTER<
--> Display returns with the prompt and a tone.
TSM DS 50-003/REV.B/031-300-190-003/12-02-96
LOAD 27C256
00000 - 07FFF=00000
39
LEVEL 3