PBX Parameter Commands
OPERATION
COMMAND
The Day/Night
*360 + X + DN + #
DN will be dialed
where:
X = 1 Day
when the
Call
X = 2 Night
button is pressed,
X = 3 Error
respective to
Destination number
Day/Night mode.
(DN) = Up to 20 digits,
The Error DN is
including *, #, Pause,
dialed after
and A-D characters. For
receiving three
special character input,
invalid Access
see section 3.6 Entering
Code entries in a
Special DTMF
row
Characters.
Delete a
*360 + X + #
destination
where:
number assigned
X = 1 Day
to Day, Night, or
X = 2 Night
Error DNs. This
X = 3 Error
command must be
entered separately
for each X value
Programming the
*170 + prefix-digit(s) +
prefix-digit(s) for
#
PBX extensions
Maximum 4 digits
dialing. When
(Do Not use * or # as
input to the
prefix digit)
PanCam-C/
Pancode begins
To cancel this
with these digits,
operation, enter:
the PanCam-C/
*170 + #
Pancode will
process them as
extension dialing
Digit(s) to open
*441 +XXXX + #
the door from any
where:
extension
XXXX= Digits (0-9)
Note: Up to 4 digits.