Nice NDA001 Programming Manual page 7

Table of Contents

Advertisement

Courtesy light: on/off
Apartment block
Stop
Emergency stop (0x28)
Interlocking (0x29)
Apartment block open
Photo
Safety function
Photo 1
Safety function
Photo 2
Safety function
Photo 3
Safety function
Release and open
Release and close
Automatic opening active
Deactivate automatic opening
Step-by-step Program the required operating
mode, ss apartment block 1 ("command configura-
tion" > "step-by-step" > operating mode: ss apart-
ment block 1)
Stop in closure Program the desired mode from
those listed in Table 1-L ("command configuration"
> "Stop in closure" > mode ...)
Opening Program the required operating mode,
apartment block 1 open ("command configuration"
> "opening" > operating mode apartment block 1
open)
Photo Program the desired mode from those listed
in Table 1-F ("command configuration" > "photo"
> mode ...)
Photo 1 Program the desired mode from those list-
ed in table 1-G ("command configuration" > "photo
1" > mode ...)
Photo 2 Program the desired mode from those list-
ed in table 1-H ("command configuration" > "photo
2" > mode ...)
Photo 3 Program the desired mode from those list-
ed in table 1-I ("command configuration" > "photo
3" > mode ...)
This command enables activation and deactivation
of the courtesy light on the control unit and that
programmable on Output 1. For the courtesy light
connected to Output 1, the command is only ena-
bled when this output is programmed in "courtesy
light" mode (Control unit functions > advanced pa-
rameters > output configuration > output 1 (flash)
> courtesy light). CAUTION! – The courtesy light is
switched off automatically if the relative time interval
elapses, as programmed in the function "courtesy
light time" (Control unit functions > advanced pa-
rameters > output configuration > courtesy light
time). Input configured as normally open.
This command is factory set to Input 1, with oper-
ating mode "ss apartment block 1" and operating
sequence "open- stop - close - open". When the
command is sent, the control unit makes the auto-
mation run the manoeuvre following that previously
(or still) in execution, according to the order of ma-
noeuvres given in the programmed sequence. Note
– This apartment block step-by-step command is
used for apartment blocks and in general envisag-
es programming of all apartment block transmitters
with a single "apartment block step-by-step" key.
Input configured as normally open.
When this command is sent, the control unit stops
the manoeuvre in progress and activates the ap-
plication to execute the set operating mode. Input
configured as normally closed.
When this command is sent, the door opens re-
gardless of its position. The input must remain
active. The safety equipment is ignored and all
close commands are also ignored (button press,
automatic closure, etc.). Only the hardware safe-
ties remain active. The door's operation is restored
when the input is deactivated. Input configured as
normally closed.
When this command is sent, the control unit stops
the manoeuvre in progress. Input configured as
normally closed. It is used together with an output
configured as Interlocking (see Interlocking output)
When this command is sent, the control unit acti-
vates the application to perform the opening ma-
noeuvre only until the limit switch is reached. Note
– This command is useful when using control pho-
tocells or a magnetic detector loop. Input config-
ured as normally open.
When this command is sent, the control unit acti-
vates the application according to the selected ma-
noeuvre type. Input configured as normally closed.
When this command is sent, the control unit acti-
vates the application according to the selected ma-
noeuvre type. Input configured as normally closed.
When this command is sent, the control unit acti-
vates the application according to the selected ma-
noeuvre type. Input configured as normally closed.
When this command is sent, the control unit acti-
vates the application according to the selected ma-
noeuvre type. Input configured as normally closed.
When this command is sent, the control unit is re-
leased (restoring normal operating status) and ac-
tivates the application to execute an Opening ma-
noeuvre. Input configured as normally open.
When this command is sent, the control unit is re-
leased (restoring normal operating status) and acti-
vates the application to execute a Closing manoeu-
vre. Input configured as normally open.
This command enables the activation or deactiva-
tion of the function for bluebus control photocells
and inputs configured in "apartment block open"
mode. Note – the factory setting of this function is
"active". For example, if this function is active, when
the control photocells are engaged, the control unit
activates the application to execute an Opening
manoeuvre. Input configured as normally open.
This command enables deactivation of the "auto-
matic opening active" mode described above. In-
put configured as normally open.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents