Nice NDA001 Programming Manual page 9

Table of Contents

Advertisement

MODE
Close - stop - close
Apartment block 1 close
Apartment block 2 close
Hold-to-run close
Stop
In this category, you can choose one of the operating modes listed in table 1-E.
MODE
Stop
Stop and brief inversion
Photo
In this category, you can choose one of the operating modes listed in table 1-F.
MODE
Stop and inversion
Stop and brief inversion
Stop
Photo 1
In this category, you can choose one of the modes listed in table 1-G.
MODE
Stop
Temporary stop
Photo 2
In this category, you can choose one of the modes listed in table 1-H.
MODE
Stop and inversion
Stop and brief inversion
Stop
Photo 3
In this category, you can choose one of the modes listed in table 1-I.
TABLE 1-D: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory (Input 3 - "close" command). This executes the
above sequence.
This executes the sequence "close - close".
This executes the sequence "close - close". Important – When sending a
command, if the transmitter key is held down for more than 2 seconds, the
control unit activates a Stop.
The Closing manoeuvre is executed exclusively if the hold-to-run command
is used.
TABLE 1-E: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory. When the control unit receives the command,
it stops the manoeuvre in progress gradually and in a short time (not instantly).
When the control unit receives the "stop" command, it stops the manoeuvre
in progress and activates the application to perform a brief inversion in the
opposite direction.
TABLE 1-F: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory. When the control unit receives the command,
it stops the Closing manoeuvre in progress and activates a total inversion
(Opening). Caution! – During execution of the Opening manoeuvre, this com-
mand is ignored.
When the control unit receives the command, it stops the Closing manoeuvre
in progress and activates the application to perform a brief inversion in the
opposite direction (Opening). Caution! – During execution of the Opening ma-
noeuvre, this command is ignored.
When the control unit receives the command is stop the current Close ma-
noeuvre. Caution! – During execution of the Opening manoeuvre, this com-
mand is ignored.
TABLE 1-G: COMMAND CONFIGURATION
DESCRIPTION
When the control unit receives the command is stop the current Close ma-
noeuvre. Caution! – During execution of the Opening manoeuvre, this com-
mand is ignored.
When the control unit receives the command, it stops the Closing manoeuvre
for the entire time that the command remains active. Otherwise, when the
command is no longer active, the control unit activates the application to
perform an Opening manoeuvre. Caution! – During execution of the Opening
manoeuvre, this command is ignored.
TABLE 1-H: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory. When the control unit receives the command,
it stops the Opening manoeuvre in progress and activates a total inversion
(Closing). Caution! – During execution of the Opening manoeuvre, this com-
mand is ignored.
When the control unit receives the command, it stops the Opening manoeu-
vre in progress and activates the application to perform a brief inversion in
the opposite direction (Closing). Caution! – During execution of the Opening
manoeuvre, this command is ignored.
When the control unit receives the command, it stops the Opening manoeu-
vre in progress. Caution! – During execution of the Opening manoeuvre, this
command is ignored.