gate closed
maintenance indicator light
Flasher
Flasher 1
Flasher at 24V
courtesy light
Always on
electric lock 1
electric block 1
suction cup 1
red traffic light
green traffic light
Interlocking (0x22)
radio channel no.1
The programmed light indicates the operating status of the control unit.
light on = application in maximum Closing position;
light off = application in other positions.
Output active 24 Vdc / max 10 W
The programmed light indicates the count of manoeuvres completed and the-
refore the need (or not) for system maintenance operations.
light on for 2 sec at start of Opening manoeuvre = number of manoeuvres
less than 80%;
light flashing during execution of entire manoeuvre = number of manoeuvres
between 80 and 100%;
light always flashing = number of manoeuvres over 100%.
This function enables the flashing light to indicate execution of a manoeuvre in
progress with flashes at regular intervals (0.5 sec ON, 0.5 sec OFF).
Output active 12 Vdc / max 21 W
This function enables the flasher to flash constantly at regular intervals (0.5
sec ON; 0.5 sec. OFF) both during a manoeuvre and when the pole is sta-
tionary.
Output active 24 V DC / max 10 W
This function enables the flashing light to indicate execution of a manoeuvre in
progress with flashes at regular intervals (0.5 sec ON, 0.5 sec OFF).
Output active 24 V DC / max 10 W
This function type is ON/OFF. Important – For safety reasons, as the light is
not controlled by a timer, use of an adequate light, able to withstand the heat
of the light emitted, is recommended.
Output active 24 Vdc / max 10 W
This function enables the indicator light to remain constantly lit both during a
manoeuvre and when the pole is stationary.
Output active 24 V DC / max 10 W
With this function programmed, when an Opening manoeuvre is performed
the electric lock is activated for a time as set in the function "electric lock time
– output configuration".
Output active 24 Vdc / max 10 W
With this function programmed, when an Opening manoeuvre is performed
the electric lock is activated for a time as set in the function "electric lock time
– output configuration".
Output active 24 dc/ max 10 VA
With this function programmed, the suction cup is activated when the appli-
cation is in the maximum Closing position. Note – The suction cup is disabled
in all other situations.
When the suction cup is disabled, before an Opening manoeuvre is started,
the time interval as programmed in the function "suction cup time – output
configuration" is activated, which delays the start of the manoeuvre.
Output active 24Vdc / max 10 W
This function indicates activity of the application during the phases of a Clo-
sing manoeuvre.
slow flashing = execution of Closing manoeuvre;
light permanently on = application in maximum Closing position;
light off = application in other positions.
Output active 24Vdc / max 10 W
This function indicates activity of the application during the phases of an Ope-
ning manoeuvre.
slow flashing = execution of Opening manoeuvre;
light permanently on = application in maximum Opening position;
light off = application in other positions.
Output active 24Vdc / max 10 W
This output is used to create the interlocking system between 2 doors. This
use enables the user to open one door, only if the other one is closed. The
output changes status when all the following conditions are valid:
- the door is closed;
- it receives a command to open;
- no safety device prevents the manoeuvre.
The output is always active when the door is any position other than totally
closed.
To establish the connection, a 24Vdc connection interface relay must be used
between this output and an input configured as Interlocking on the second
control unit.
If this radio channel is set for the configuration of output 1 (flash), this channel
is activated when a command is set with the transmitter. It is useful if installing
external devices (for example, an auxiliary light) in the same system to be
controlled with a single transmitter.
WARNING – If this channel is not free on the control unit receiver, as previously
memorised with a command, the control unit activates exclusively the pro-
grammed output when the channel is activated with the transmitter, ignoring
the command to the motor.
Output active 24Vdc / max 10 W