Output Configuration - Nice NDA001 Programming Manual

Table of Contents

Advertisement

MODE
Temporary stop
Stop
Alt in opening
In this category, you can choose one of the modes listed in table 1-L.
MODE
None
Stop
Stop and brief inversion
Alt and inversion
Stop in closure
In this category, you can choose one of the modes listed in table 1-M.
MODE
None
Stop
Stop and brief inversion
Alt and inversion
Stop in pre-closure (0x6e)
In this category, you can choose one of the modes listed in table 1-N for sensitive edge intervention within the inhibition position
MODE
Stop
None

OUTPUT CONFIGURATION

This item covers the functions available and associable with Outputs 1 (flash) - 2 - 3 present on the control unit of an automation. Each output has various
functions as described in a table (Table 2, Table 3, etc.):
OUTPUT
Traffic Light Output
The following connections are available:
8. Common 24V
9: output OUT-TL1
10: output OUT-TL2
11: output OUT-TL3
FUNCTION
Red traffic light (0x0d)
TABLE 1-I: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory. When the control unit receives the command,
it stops the Closing manoeuvre for the entire time that the command remains
active. Otherwise, when the command is no longer active, the control unit
activates the application to perform an Opening manoeuvre.
When the control unit receives the command, it stops the manoeuvre in pro-
gress.
TABLE 1-L: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory. When this type of function is set, when the
control unit receives the command, it stops the Opening manoeuvre in pro-
gress immediately.
When the control unit receives the command, it stops the Opening manoeuvre
in progress immediately and activates the application to perform a brief inver-
sion in the opposite direction (Closing).
When the control unit receives the command, it immediately stops the Closing
manoeuvre in progress and activates the application to perform a total inver-
sion of the manoeuvre in the opposite direction (Opening).
TABLE 1-M: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory. When the control unit receives the command,
it stops the Closing manoeuvre in progress.
When the control unit receives the command, it stops the Closing manoeuvre
in progress immediately and activates the application to perform a brief inver-
sion in the opposite direction (Opening).
When the control unit receives the command, it immediately stops the Closing
manoeuvre in progress and activates the application to perform a total inver-
sion of the manoeuvre in the opposite direction (Opening).
TABLE 1-N: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory. When the control unit receives the command,
it immediately stops the Closing manoeuvre in progress.
The edge is ignored and the manoeuvre continues until the door reaches the
set closed position.
TABLE 1: OUTPUT CONFIGURATION
DESCRIPTION
This function indicates activity of the application during the phases of a Clos-
ing manoeuvre.
slow flashing = execution of Closing manoeuvre;
light permanently on = application in maximum Closing position;
light off = application in other positions.
The OUT-TL2 output at 24V DC / max 5W is used