Environmental Conditions

This instrument is designed for indoor use and in an area with low condensation.
The table below shows the general environmental requirements for this
instrument.
Environmental cond ition
Operating temperature
Operating humidity
Storage temperature
Altitude
Pollution degree
The U1190A Series Handheld Clamp Meter complies with the following safety
NOTE
and EMC requirements:
– IEC 61010-1:2001/EN 61010-1:2001
– IEC 61010-2-032:2002/EN 61010-2-032:2002
– CAN/CSA-C22.2 No. 61010-1-04
– CAN/CSA-C22.2 No. 61010-2-032-04
– ANSI/UL Std. No. 61010-1:2004
– IEC61326-1:2005/EN61326-1:2006
– Canada: ICES/NMB-001: Issue 4, June 2006
– Australia/New Zealand: AS/NZS CISPR 11:2004
Keysight U1190A Series Service Guide
Requirement
–10 °C to 50 °C
Up to 80% RH (relative humidity) for temperature up to 30 °C,
decreasing linearly to 50% RH at 50 °C
–40 °C to 60 °C, 40% to 80% RH (without batteries)
Up to 2000 meters
Pollution Degree 2